June 17, 2019
7058-803B
13
ECO CHOICE PELLET
7 AMP FUSE
JUNCTION BOX
HI / LOW SWITCH
FUSE
T .C .
PURPLE
PURPLE
WHITE
WHITE
#1 SNAP DISC
BLACK
BLACK
A / 1
B / 2
C / 3
D / 4
E / 5
F / 6
H / 7
J / 8
K / 9
L / 10
M / 11
N / 12
P / 13
R / 14
S / 15
CONVECTION
BLOWER
CONVECTION BLOWER CIRCUIT
CONVECTION BLOWER TESTING WITH TEST BOX
(IN CONJUNCTURE TO THIS SERVICE MANUAL USE THE INSTRUCTION SHEET FOR THE TEST
BOX KIT)
1. Unplug the appliance, remove the control box, install the test box, and plug the appliance back in.
2.
Install a jumper wire onto the #1 snap disc purple wires and then plug in the appliance.
3. Turn on the convection blower switch.
- If the blower comes on:
–
Replace #1 snap disc
– Replace the control box
- If the blower does not come on:
– Check the wire harness
– Replace the blower