Approvals

The Heat-Zone

® 

240V air duct kit is approved for use on 

Heat & Glo Models  XLR-AU, XLR-PLUS, XLR-CE, RED40-

AU, 6TRSI-AUD, MEZZO-AU, 6000, 350 and 550 series 

gas heaters.

Introduction

The Heat-Zone

®

 240V accessory kit conveys warm air 

from the heater through air duct(s) to remote locations in 

the same room or other rooms of the building. See Figure 

1. One or two Heat-Zone

®

 240V kits can be installed on 

the heater.

Preliminary Preparation

Contents of kit:

•  6 meters of 152 mm Round Duct
•  Fan Housing Assembly
•  Junction Box
•  Air Register
•  Heater Duct Collar
•  Duct Adapter - (round to oval)
•  Hardware Bag
•  IPI Plus Auxiliary Jumper

Heat-Zone

®

 240V Air Duct Kit

NOTICE! 

If any parts are missing or damaged, contact your 

dealer before starting installation.  DO NOT install a damaged kit.

FLOOR REGISTER

TWO DUCT KITS

WALL REGISTER

    WALL 

REGISTER

   

WALL 

REGISTER

CEILING REGISTER

Figure 1

Possible Air Duct Runs/Locations

457 mm

171 mm

MINIMUM SPACE 

REQUIRED FOR 

90 DEGREE BEND

Summary of Contents for Heat-Zone 240V

Page 1: ...oms of the building See Figure 1 One or two Heat Zone 240V kits can be installed on the heater Preliminary Preparation Contents of kit 6 meters of 152 mm Round Duct Fan Housing Assembly Junction Box Air Register Heater Duct Collar Duct Adapter round to oval Hardware Bag IPI Plus Auxiliary Jumper Heat Zone 240VAir Duct Kit NOTICE If any parts are missing or damaged contact your dealer before starti...

Page 2: ...U The Heat Zone 240V kit is tested and safe when installed in accordance with this installation manual This kit is carefully engineered and must be installed only as speci fied Modifying the kit or any of its components will void the warranty and may possibly cause a fire hazard CAUTION Installation of this appliance should only be carried out by an authorized person All relevant codes and regulat...

Page 3: ...E 240 VAC will be provided by AUX300CE module Connect 2166 191 jumper to AUX1 of AUX300CE module Using wire connectors secure wires to 2166 191 jumper and run to fan junction box Inside of fan junction box secure wires to fan wires using wire con nectors and screw the ground wire to the fan junction box See figure 9 10 Screw the fan junction box to the fan housing 11 Screw the register to the fan ...

Page 4: ... BOX CONNECTION WIRE SUPPLIED BY INSTALLATION PROFESSIONAL Isolated ON OFF Control Wall Switch IPI Plus with Auxiliary Control Please contact your Hearth Home Technologies dealer with any questions or concerns For the location of your nearest Hearth Home Technologies dealer please visit www hearthnhome com Hearth Home Technologies 7571 215th Street West Lakeville MN 55044 www hearthnhome com Opera...

Reviews: