Hearth & Home Technologies • Heat-Zone-240V Air Duct Kit • 299-900 Rev. H • 11/15
4
BROWN
BLUE
GREEN/YELLOW
BLUE
FAN
BROWN
GROUND
FAN
JUNCTION BOX
CONNECTION WIRE SUPPLIED BY
INSTALLATION PROFESSIONAL
WALL
SWITCH
BROWN
BLUE
FAN
AUX1 AUX2
GROUND
FAN
JUNCTION BOX
2166-191 JUMPER
CONNECTION WIRE SUPPLIED BY
INSTALLATION PROFESSIONAL
APPLIANCE
JUNCTION CORD
GREEN
WHITE
BLACK
Figure 8
Figure 9
BLUE
BROWN
AUX1= 3 FAN SPEEDS
AUX2= ON/OFF CONTROL HIGH ONLY
GREEN/
YELLOW
BROWN
BLUE
GREEN/YELLOW
BLUE
WHITE
FAN
BROWN
BLACK
AUX1 AUX2
GROUND
FAN
JUNCTION BOX
2166-191 JUMPER
APPLIANCE
JUNCTION BOX
CONNECTION WIRE SUPPLIED BY
INSTALLATION PROFESSIONAL
Isolated ON/OFF Control Wall Switch
IPI Plus with Auxiliary Control
Please contact your Hearth & Home Technologies dealer
with any questions or concerns.
For the location of your nearest Hearth & Home
Technologies dealer,
please visit www.hearthnhome.com.
Hearth & Home Technologies
7571 215th Street West, Lakeville, MN 55044
www.hearthnhome.com
Operation
1. Start the heater per instructions and allow it to warm
up.
2. Turn the wall switch "ON" to start air flow at the air duct
register or use RC300 remote to turn on blower.
Maintenance
1. Service and maintain the gas heater per instructions.
2. Keep the air register(s) clean and free of any blockage.
3. Reference IPI Plus instructions with remote control for
fan auxiliary control.