Hearth & Home Heat-Zone 240V Installation And Operation Instructions Download Page 4

Hearth & Home Technologies  •  Heat-Zone-240V Air Duct Kit  •  299-900 Rev. H  •  11/15

4

BROWN

BLUE

GREEN/YELLOW

BLUE

FAN

BROWN

GROUND

FAN

JUNCTION BOX 

CONNECTION WIRE SUPPLIED BY 

INSTALLATION PROFESSIONAL

WALL 

SWITCH 

BROWN

BLUE

FAN

AUX1 AUX2

GROUND

FAN

JUNCTION BOX 

2166-191 JUMPER

CONNECTION WIRE SUPPLIED BY 

INSTALLATION PROFESSIONAL

APPLIANCE

JUNCTION CORD 

GREEN

 WHITE

BLACK

Figure 8

Figure 9

BLUE

BROWN

AUX1= 3 FAN SPEEDS

AUX2= ON/OFF CONTROL HIGH ONLY

GREEN/

YELLOW

BROWN

BLUE

GREEN/YELLOW

BLUE

WHITE

FAN

BROWN

BLACK

AUX1 AUX2

GROUND

FAN

JUNCTION BOX 

2166-191 JUMPER

APPLIANCE

JUNCTION BOX 

CONNECTION WIRE SUPPLIED BY 

INSTALLATION PROFESSIONAL

Isolated ON/OFF Control Wall Switch

IPI Plus with Auxiliary Control

Please contact your Hearth & Home Technologies dealer 

with any questions or concerns. 

For the location of your nearest Hearth & Home 

Technologies dealer, 

please visit www.hearthnhome.com.

Hearth & Home Technologies  

7571 215th Street West, Lakeville, MN 55044

www.hearthnhome.com

Operation

1.  Start the heater per instructions and allow it to warm 

up. 

2.  Turn the wall switch "ON" to start air flow at the air duct 

register or use RC300 remote to turn on blower.

Maintenance

1.  Service and maintain the gas heater per instructions.
2.  Keep the air register(s) clean and free of any blockage. 
3.  Reference IPI Plus instructions with remote control for 

fan auxiliary control.

Summary of Contents for Heat-Zone 240V

Page 1: ...oms of the building See Figure 1 One or two Heat Zone 240V kits can be installed on the heater Preliminary Preparation Contents of kit 6 meters of 152 mm Round Duct Fan Housing Assembly Junction Box Air Register Heater Duct Collar Duct Adapter round to oval Hardware Bag IPI Plus Auxiliary Jumper Heat Zone 240VAir Duct Kit NOTICE If any parts are missing or damaged contact your dealer before starti...

Page 2: ...U The Heat Zone 240V kit is tested and safe when installed in accordance with this installation manual This kit is carefully engineered and must be installed only as speci fied Modifying the kit or any of its components will void the warranty and may possibly cause a fire hazard CAUTION Installation of this appliance should only be carried out by an authorized person All relevant codes and regulat...

Page 3: ...E 240 VAC will be provided by AUX300CE module Connect 2166 191 jumper to AUX1 of AUX300CE module Using wire connectors secure wires to 2166 191 jumper and run to fan junction box Inside of fan junction box secure wires to fan wires using wire con nectors and screw the ground wire to the fan junction box See figure 9 10 Screw the fan junction box to the fan housing 11 Screw the register to the fan ...

Page 4: ... BOX CONNECTION WIRE SUPPLIED BY INSTALLATION PROFESSIONAL Isolated ON OFF Control Wall Switch IPI Plus with Auxiliary Control Please contact your Hearth Home Technologies dealer with any questions or concerns For the location of your nearest Hearth Home Technologies dealer please visit www hearthnhome com Hearth Home Technologies 7571 215th Street West Lakeville MN 55044 www hearthnhome com Opera...

Reviews: