Service Parts List  /   Liste des pièces de rechange

ITEM /

PIÈCE

STANDING PILOT AND DSI IGNITION COMMON PARTS

 / UNE VEILLEUSE ET ALLUMAGE DSI PIÉCES COMMUNES

SERIAL # / N°

DE SÉRIE

PART NUMBER

/ N° DE PIÈCE

Piezo Ignitor  /   Allumage Piézo

418-513

Burner Orifice NG (#38)  /  Orifice de brûleur 

  

GN (#38)

582-838

Burner Orifice LP (#51)  /  Orifice de brûleur PL (#51)

582-851

1

Surround  /  Entourent

385-130

2

Hood  /  Hotte

SRV60-143-BK

3

Glass Door Assembly   /  Module de Porte en verre

GLA-750TR

4

Burner NG  /  Brûleur GN

381-376A

4

Burner LP  /  Brûleur PL

381-375A

5

Log Grate  /  Grille de Bûche

060-361A

6

Log Set  Assembly  (Only sold as a set) /  Module de Jeu de Bûches

LOGS-BE41

7

Junction Box  /  Boîtier de raccordement

100-250A

8

Louver, Bottom  / Louvre, inférieure

394-114

9

Louver, Top  / Louvre, supérieure

394-249

11

Flex Ball Valve Assembly  /  Fléchir l'Assemblée de Soupape de Balle

302-230A

12

Base Refractory  /  Base réfractaire

381-124

13

Insulation Board  /  Conseil d'Isolation

385-401

Tube Assembly  /  Module de Tube

477-301A

STANDING PILOT IGNITION ONLY / ALLUMAGE UNE VEILLEUSE SEULEMENT

10

Valve Plate Assembly  NG / NG d'Assemblée de Plaque de soupape

381-005A

10

Valve Plate Assembly  LP / LP d'Assemblée de Plaque de soupape

381-006A

Valve NG  /  Valve GN

060-522

Valve LP  /  Valve PL

060-523

Pilot Assembly NG  /  Module de veilleuse GN

485-510A

Pilot Assembly LP /  Module de veilleuse PL

485-511A

Thermocouple  /  Thermocouple

446-511

Thermopile  /  Thermopile

060-512

Intermittent Pilot Ignition / Parties d'Ignition Pilotes Intermittentes

7

Junction Box  /  Boîtier de dérivation

383-250A

10

Valve Assembly NG /  Module de Valve  GN

381-007A

Valve NG  / Valve GN

750-500

Valve LP  /  Valve PL

750-501

Ignitor Assembly NG  / Module de allumeur GN

385-510A

Ignitor Assembly LP  / Module de allumeur PL

385-511A

Wire Harness  / Harnais de fil

593-590A

3V Transformer  / 3V Transformateur

593-593A

Module  /  Module

593-592

ON/OFF Rocker Switch  /  Interrupteur à bascule MARCHE/ARRÊT

060-511

Battery Backup  /  Sauvegarde de pile

593-594A

ACCESSORIES  /  ACCESSOIRES

Conversion Kit NG  /  Module de conversion GN

NGK-BE41B

Conversion Kit LP  /  Module de conversion PL

LPK-BE41B

Conversion Kit IPI LP  /  Module de conversion  IPI PL

LPK-BE41B-IPI

Brass Trim Kit  /   Laiton Coupe Kit

PBK-BE41

IMPORTANT: 

THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,

supply serial and model numbers to ensure correct service parts. / 

IMPORTANT :

 L'information fournie dans cette brochure n'est

valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une
commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.

BE-41B

u

u

u

u
u

Summary of Contents for BE-41B

Page 1: ...REFERENCE 1 This appliance may be installed in an af termarket permanentlylocated manufac tured mobile home wherenotprohibited by local codes 2 This appliance is only for use with the type of gas ind...

Page 2: ...DERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the firs...

Page 3: ...3 Installing the Vent System 12 A Vent System Approvals 12 B Installing Vent Components 19 C Vent Termination 22 Step 4 Positioning Leveling and Securing the Fireplace 25 Step 5 The Gas Control System...

Page 4: ...e des num ros de pi ce se trouve la page suivante 2 3 1 8 9 10 5 7 6 Log Set Assembly 4 NG LP Exploded Parts Diagram GN PL Vue clat e des pi ces Service Parts BE 41B Beginning Manufacturing Date 5 02...

Page 5: ...0 523 Pilot Assembly NG Module de veilleuse GN 485 510A Pilot Assembly LP Module de veilleuse PL 485 511A Thermocouple Thermocouple 446 511 Thermopile Thermopile 060 512 Intermittent Pilot Ignition Pa...

Page 6: ...ce with local codes or in the absence of local codes with the National Electric Code ANSI NFPA No 70 in the United States or to the CSA C22 1 Canadian Electric Code in Canada These models may be insta...

Page 7: ...to follow these instructions will void the owner s warranty and may present a fire hazard The Hearth Home Technologies Warranty will be voided by and Hearth Home Technologies disclaims any responsibil...

Page 8: ...LS RATING PLATE AND LABELS LOWER LOUVER HOOD TOP STANDOFFS TOP LOUVER 41 1043mm 38 965mm 36 1 8 916mm 25 642mm 34 5 8 879mm 8 5 8 219mm VENT COLLARS ELECTRICAL ACCESS 26 7 8 683mm 10 259mm 3 90mm GAS...

Page 9: ...THESE INSTRUCTIONS ARE NOT SUBSTITUTES FOR THE REQUIREMENTS OF LOCAL BUILDING CODES THEREFORE YOUR LOCAL BUILD ING CODES MUST BE CHECKED TO DETERMINE THE REQUIREMENTS FOR THESE STEPS Factory built fir...

Page 10: ...ng material The dia gram below shows framing reference dimensions CAUTION MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING 1 2 CLEARANCE FROM BACK OF FI...

Page 11: ...36D 5 3 4 146mm 8 3 4 222mm 11 3 4 298mm DV 48D 7 3 8 187mm 6 5 32 156mm 11 5 8 295mm 8 5 8 220mm 8 1 2 216mm 6 7 16 164mm 11 1 16 281mm 6 1 2 165mm 8 1 2 216mm 5 1 16 129mm 8 5 8 220mm 35 3 4 908mm...

Page 12: ...dentifying Vent Components The vent systems installed on this gas fireplace may in clude one two or three 90 elbow assemblies The rela tionships of vertical rise to horizontal run in vent configura ti...

Page 13: ...want to install the vertical baffle 385 128 See flue restrictor installation in structions Figure 6 Flex Vent The flex vent must be supported with the spacing between support intervals not exceeding...

Page 14: ...tem with the chart to find the appropriate position to set the Flue Restrictor 1 2 3 4 5 SETTINGS 1 2 3 4 5 Figure 10 CHART Vertical Top Vent NG Top Vent LP Rear Vent NG Rear Vent LP 4 1 1 No Restrict...

Page 15: ...914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m V H 40 MAX 12 4MM H 20 MAX 6 2m Figure 13 Venting with One 90 Elbow NOTE If a 90o elbow is first attached to the unit the maximum horizontal run is 3 feet 91...

Page 16: ...Venting with Two 90 Elbows VENTING WITH TWO 2 90o ELBOWS V FT H H1 FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m V H H1 40 MAX 12 4m H H1 20 MAX 6...

Page 17: ...V H H1 H2 40 MAX 12 4 m H 8 MAX 2 48 m H H 1 H2 20 MAX 6 2 m V H H H1 H2 1 MIN 305mm 2 MAX 610mm 5 MAX 1 52m 2 MIN 610mm 4 MAX 1 22m 10 MAX 3 1m 3 MIN 914mm 6 MAX 1 86m 15 MAX 4 65m 4 MIN 1 22m 8 MAX...

Page 18: ...1 H H1 40 MAX 12 4m V FT H H1 FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m H H1 20 MAX 6 2m NOTE V V1 H H1 40 MAX 12 4m Figure 17 Venting with th...

Page 19: ...erglass gasket supplied in the man ual bag seals between the first 8 5 8 inch 219mm vent component and the outer fireplace wrap Using 2 self tapping screws from the manual bag secure that gasket to th...

Page 20: ...l brackets to the vent pipe and secure the wall bracket to the framing members with nails or screws Figure 22 Installing Support Brackets 4 Install Firestops For Horizontal Runs Firestops are REQUIRED...

Page 21: ...ical runs that pass through ceilings Position a plumb bob directly over the center of the verti cal vent component Mark the ceiling to establish the centerpoint of the vent Drill a hole or drive a nai...

Page 22: ...E WALL VENTING TERMINALS SHALL NOT BE RE CESSED INTO AWALL OR SIDING SEE THE FOL LOWING DIAGRAM FOR VENT TERMINATION CLEARANCES TRAPEZOID CAP TERMINATION 7 1 4 184mm WARNING THETERMINATIONCAPMUSTBEPO...

Page 23: ...RONGLY RECOMMENDED WHENEVER POSSIBLE TO USE THE VINYL PROTECTOR KIT 30 minimum for vinyl clad soffits a vent shall not terminate directly above a sidewalk or paved driveway which is located between tw...

Page 24: ...FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMI NATION CAP IS AT LEAST TWO 2 FEET FROM A VERTICAL WALLAND 2 FEET BELOW AHORIZON TAL OVERHANG NOTE This also pertains to vertical vent systems...

Page 25: ...Figure 32 Gas Controls Systems Step 5 The Gas Control Systems WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL Two types of gas control systems are used with these models Standing Pilot Ignition and...

Page 26: ...h non combustible insulation to pre vent cold air infiltration Open the fireplace lower grille insert the gas supply line throughthegaslinehole andconnectittotheshut offvalve When attaching the pipe s...

Page 27: ...witch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF switch pigtails WARNING D...

Page 28: ...nstalled junction box before the fire place is permanently installed Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G mi...

Page 29: ...GAtesting standards donot require hearth extensions for gas fireplace appliances Figure 38 Sealant Material 2 4 5 6 7 8 9 2 3 4 5 12 11 10 9 8 7 6 TOP FRONT EDGE OF FIREPLACE 3 11 12 10 31 CEILING 1 1...

Page 30: ...of the tie in the fireplace see Figure 40 WARNING USE WIRE CUT TERS DO NOT ATTEMPT TO CUT THE TIE WITH A KNIFE 3 Grasp the log assembly by the ends Do NOT grasp the log as sembly by the center Remove...

Page 31: ...ut shrink wrap and remove from around the log assembly WARNING REMOVE ALL PACKAGING FROM LOGS 8 Install embers See ember placement instructions for details WARNING USE DIME SIZE PIECES ONLY DO NOT COV...

Page 32: ...er material is shipped with this gas fireplace To place the ember material Pull the four glass latches out of the groove on the glass frame Remove glass door from the unit see Figure 44 Place dime siz...

Page 33: ...e thermopile thermocouple tips should be covered with flame See Figure 32 Figure 46 Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADY NOT LIFTING OR FLOATING Checking Vent System Frequency Before...

Reviews: