A. Securing and Leveling Appliance

CAUTION!

  Risk  of  cuts,  abrasions  or  flying 

debris. 

Wear protective gloves and safety glasses 

during installation. Sheet metal edges are sharp.

Position, level and secure the appliance.

•  Place the appliance into position on either 

a  wood  or  noncombustible  continuous  flat 

surface.

•  Level the appliance from side to side and front 

to back.

• 

Shim  the  appliance  with  noncombustible 

material, such as sheet metal, as necessary.

•  Chase platforms, including hearths, should 

slope away from the structure at 1/8 inch to 

1/4 inch per foot.

• 

Nailing  tabs  must  be  moved  from  shipping 

position to installation position and secured 

to framing. Bend the four nailing tabs out on 

each side. See Figure 4.1.

B. Flashing

•  Flash the appliance in a manner consistent 

with regional practices to prevent water 

penetration around the appliance. Due to 

elevated temperatures across the top of the 

appliance, metal flashing and high temperature 

sealant  must  be  used.  Adhesive  polymers 

flashing materials may melt.

• 

For  brick,  stone,  stucco  and  similar 

construction, weep screeds should be installed 

per regional codes.

•  See Section 3.F. and Figures 3.2. for more 

information regarding wall and enclosure 

construction required to prevent moisture 

penetration into the structure. The appliance 

will shed moderate amounts of water but is not 

waterproof.

NOTE

: Use high temp silicone or sealant 

recommended by the manufacturer of the house 

wrap  to  seal  between  combustible  sheathing 

house wrap and non-combustible sheathing.  The 

sealant material used within 6 inches of the top 

and 1 inch on the sides of the appliance surround 

must  be  approved  to  withstand  a  minimum 

temperature of 225°F continuous exposure.

House wrap tape with a 225°F minimum 

temperature may also be used.  See Figure 4.2.

Nailing Flanges

(both sides)

Appliance Preparation 

Figure 4.1. 

Positioning and Securing Nailing Tab

1 in.

6 in.

Membrane Overlap

Dotted Lines

Figure 4.2. 

Membrane Overlap

Summary of Contents for Outdoor Lifestyles ODLANAIGST-48

Page 1: ...structions could result in fire or explosion which could cause property damage personal injury or death WARNING Do not store or use gasoline or other flammable va pors and liquids in the vicinity of t...

Page 2: ...gn and Installation Considerations 5 B Tools and Supplies Needed 5 C Inspect Appliance and Components 6 3Framing and Clearances A Appliance Dimension Diagrams 7 B Clearances to Combustibles 8 C Vent M...

Page 3: ..._______________________________ all clearances meet installation manual requirements ________________________________________ Mantels and wall projections comply with installation manual requirements...

Page 4: ...slate glass plasters or any combination thereof Materials that are reported as passing ASTM E 136 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C shall be considered...

Page 5: ...inlets gas meters etc Location of the appliance to a door that swings open to ensure it doesn t interfere with the appliance when opened Location of Windows Location of Walkways Possibility of floodi...

Page 6: ...tallation to ensure maximum safety and benefit WARNING Risk of Fire or Explosion Damaged parts could impair safe operation DO NOT install damaged incomplete or substitute components Hearth Home Techno...

Page 7: ...ns are actual appliance dimensions Use for reference only For framing dimensions and clearances refer to Figure 3 2 and Figure 3 3 Figure 3 1 Appliance Dimensions ODLANAIGST 48 39 1 2 in 1003 mm 17 in...

Page 8: ...may cause flames to reach out in front Keep furniture draperies and other combustibles away Locate the appliance away from traffic areas Clean up fallen leaves branches and other combustible materials...

Page 9: ...s and the appliance face in a manner consistent with regional practices as required to prevent water penetration around the appliance See Section 3 F for more information regarding wall and enclosure...

Page 10: ...All mechanical air intakes within 10 feet of a horizontal termination cap must be a minimum of 3 feet below termination 3 ft 914 mm 6 ft 1829 mm J For appliances installed facing or opening onto publi...

Page 11: ...es that may rot or otherwise be damaged by water See also Section 4 B Built in Installation When this appliance is installed into a wall we recommend that the wall be an exterior wall system See frami...

Page 12: ...cture at 1 8 in to 1 4 in per foot The appliance can be shimmed level Water Drainage The Lanai is designed to operate outdoors experiencing rain and other sources of moisture that will enter the fireb...

Page 13: ...ation around the appliance Due to elevated temperatures across the top of the appliance metal flashing and high temperature sealant must be used Adhesive polymers flashing materials may melt For brick...

Page 14: ...s prior to disconnection when servicing controls Wiring errors could cause improper and dangerous operation Verify proper operation after servicing B IntelliFire Pilot Ignition System Wiring Wire the...

Page 15: ...allation Manual 4113 901 Rev D 8 21 Wire junction box and reassemble See Figure 5 1 Plug in transformer and power supply to junction box See Figure 5 4 Black and white wires must be wired inside box F...

Page 16: ...RANGE WHITE BROWN WIRES RED BLACK WIRES NOT USED LED STRIP LED STRIP TRANSFORMER LED CONTROL MODULE JUNCTION BOX TOP BUTTON ON HI MED LO OFF BOTTOM BUTTON Color Selection 3 RED BLUE YELLOW GREEN RED B...

Page 17: ...of the unit Locate controls by lifting engine and using support legs To access Intellifire control module and LED control module lift control box cover off of controls The rocker switch wire Black whi...

Page 18: ...ternational Fuel Gas Code Note Have the gas supply line installed in accordance with local codes if any If not follow ANSI Z223 1 Installation should be done by a qualified installer approved and or l...

Page 19: ...e loosened during shipping and handling WARNING Risk of Fire or Explosion Gas build up during line purge could ignite Purge should be performed by a qualified service technician Ensure adequate ventil...

Page 20: ...dealer prior to installation Mantel and Wall Projections WARNING Risk of Fire Comply with all minimum clearancestocombustibleasspecified Framingor finishing material closer than the minimums listed m...

Page 21: ...operating temperatures can vary from manufacturer to manufacturer and from model to model actual TV temperatures should be validated at the time of each installation TVs should not be used in situati...

Page 22: ...ith this appliance Using non listed accessories could result in a safety hazard and will void the warranty D Verify Pilot Shield Ensure proper placement of the pilot shield and media placement templat...

Page 23: ...48CFT The Lanai series outdoor gas appliance offers a trim kit that will allow the owner the option to cover the face of the appliance down to the firebox opening This four 4 piece kit comes with an i...

Page 24: ...space 20 72 28 28 is less than the 30 required and therefore this installation would not be approved 1 Add lengths of the outside living space 12 20 12 20 64 2 Divide the open area length by the total...

Page 25: ...1 Rev D 8 21 Outdoor Lifestyles a brand of Hearth Home Technologies 2571 215th Street West Lakeville MN 55044 www hearthnhome com Please contact your Outdoor Lifestyles dealer with any questions or co...

Reviews: