Wall Control - WSK300

Control Specifi cations

13

/&&

4(%2-/34!4

/.

0),/4

4)-%2

-/$%

!58

AUXILIARY button

Function - AUXILIARY features

Press UP or DOWN 
arrow buttons to 
determine desired 
setting

Wall Control

First press the 

!58

 button multiple times 

to scroll through to the desired Auxiliary 
feature (A1, A2, or A3).

If desired Auxiliary selected is A1 or A2 
use the UP or DOWN 

 arrow to step 

through the following 4 levels:

Auxiliary Features

!58

The           button will operate the 
following 3 auxiliary features:

A1 

= FAN (always room heating)

A2 

= SWITCHES 110VAC, HI/MED/LOW

A3 

= SWITCHES 110VAC, ON/OFF

AUXILIARY function 
level indicator

• 

Upon entering the OFF mode, all auxiliaries will be turned off with 
the fi replace with the exception of A1 after leaving THERMOSTAT 
mode. This mode activates a FAN cool-down feature that will 
continue to operate the fan until all remaining heat has been 
blown into the room.Auxiliary A1 (FAN) may not be operated in 
the OFF mode, as this auxiliary is always a room-heating fan.

• 

A1 may be operated during the ON mode as desired. During the 
THERMOSTAT mode A1 (FAN) will be adjusted automatically 
(between OFF, L1 and L2) based on the desired room 
temperature setting. It will also perform a warm-up when entering 
THERMOSTAT mode, and cool-down when the fl ame is no longer 
necessary to heat the room. This allows energy to be conserved 
as the fan will only operate when the fi replace is warm.

&! .

• 

Auxiliaries A2 and A3 may 
be adjusted in any of the 
3 modes. When the ON or 
THERMOSTAT mode is active 
these settings will be saved 
to memory and set back to 
the desired levels when ON 
or THERMOSTAT mode is 
activated again.

OFF

L1

 = Low

 

L2 

= Medium

L3 

= High

Summary of Contents for Multifunction Wall Control WSK300

Page 1: ...nder it unusable and may lead to possible electrical shock Fire Hazard Modification of any parts or installation of dama ged components will void the warranty and you may possibly cause a fire hazard...

Page 2: ...and blue and red plungers from the side of the flame control sole noid Place washer on flame control solenoid 4 Insert correct plunger blue natural gas red pro pane into the flame control solenoid Thr...

Page 3: ...PILOT DEXEN IPI VALVE CONTROL MODULE SOLENOID J BOX 110V FAN WALL SWITCH BACK VIEW CORD ASSEMBLY 2 GRN BLK BLK JUMPER DETAIL B B FOR B VENT APPLIANCES BLU SEE DETAIL B B FOR B VENT APPLIANCES HIGH LI...

Page 4: ...unit as close to the louvers or decorative front as possible and to either the left or right side 2 Connect the red yellow or white and green wires to the appropriate labeled terminals on the control...

Page 5: ...o pilot functions PILOT ON will always be highlighted on display for cold climate pilot operation PILOT OFF will be displayed when in normal pilot operation for three seconds Use AUX button to toggle...

Page 6: ...ntrol Specifications 6 Function CONTINUOUS DISPLAY SCREEN 4 2 34 4 0 4 4 2 3 4 2 4 0 6 4 2 3 4 54054 0 4 58 3 4 2 4 0 6 4 2 3 4 54054 0 4 At a continuous display mode LCD will only display the room te...

Page 7: ...ivate the temperature scale change Fahrenheit icon will appear with the temperature level Press both arrow buttons for three seconds to change temperature scale between F and C 3 4 2 4 0 6 4 2 3 4 540...

Page 8: ...ws to turn flame HI or LO Pressing the UP or DOWN arrow while the continuous display screen is shown will display the current flame size Wall Control HI Flame LO Flame Adjusting Flame Size Pressing UP...

Page 9: ...ay Pilot flame will stay lit continuously 0 4 Press PILOT button 3 4 2 4 0 6 4 2 3 4 54054 0 4 PILOT icons will display Press button until OFF setting is highlighted Normal display will have no PILOT...

Page 10: ...o lock any button press from changing the state of the fireplace or its features To cancel the Child Lockout Feature press and hold the button again for 3 seconds The control will beep twice again and...

Page 11: ...to a maximum of 180 minutes Press DOWN arrow to decrease TIMER setting in 15 minute decrements to a minimum of 15 minutes To change TIMER settings while the TIMER is active press button twice Then Pre...

Page 12: ...ode will automatically adjust fireplace Flame Size and Fan Speed based on the desired room temperature If AUX 1 Fan is pressed AUT will display on the screen When the control is first powered the THER...

Page 13: ...ing THERMOSTAT mode This mode activates a FAN cool down feature that will continue to operate the fan until all remaining heat has been blown into the room Auxiliary A1 FAN may not be operated in the...

Page 14: ...the line voltage power supply and then removing the batteries from the battery backup kit if it is at tached After one minute restore the line voltage power supply and the batteries The wall control s...

Page 15: ...all switch will come back on the pilot will stay on and the fireplace will stay off The wall switch is in OFF mode with the main flame off and has no battery backup or has dead batteries The fireplace...

Page 16: ...itch is in OFF mode with the main flame off and it has battery backup The fireplace main burner will stay off The display lights in the wall switch will be off and the fireplace can be turned on and o...

Reviews: