3.  Install the Fan

Position the fan all the way to the rear and center in the 

appliance. Press the fan (magnets to the bottom) to the 

back of the appliance.  See Figure 7. Plug the fan cord 

into the fan receptacle labeled “FAN” on the junction box. 

See Figure 8.

BOTTOM PAN

APPLIANCE

BACK

FAN

FIREBOX

BOTTOM

Figure 7 

Rotate Fan

Junction Box

Fan Assembly

Cord

Clips

Figure 8 

Position the Fan

5.  Wiring the Fan Control Module

Wall 

Switch 

RS 

Valve 

TP 

TH 

TH  TP 

Fan 

Control 

Module 

Black/White

Black Ground

Black 

Red 

White 

Thermopile 

Red 

White 

Figure 9 

Robertshaw Wiring Diagram

4.  Install the Control Module

Attach the control module to the bottom pan using the mag-

netic tape provided.

Note: 

Fan control timer only for use on units with junction 

box pictured in Figure 9.

•  Robertshaw Valve (Standing Pilot)

-  Connect the black, white and red wires with 1/4 in. 

female connectors from the fan control module to the 

appliance junction box as shown in Figure 9.

-  Connect the black ground wire with the ring terminal 

to the TP screw on the valve (center).

-  Remove wall switch wire connected to valve terminal 

marked “TH”.

-  Connect the black with white stripe wire with 3/16 in. 

piggyback connector from fan control module to valve 

terminal marked “TH”.

-  Connect wall switch wire removed from valve terminal 

“TH” to the piggyback connector on the black with white 

stripe fan control module wire.

Note: 

Thermopile must be wired as shown in Figure 9.