background image

INDOOR AIR QUALITY 

KIT AND ACCESSORIES

504887-01 

10/2021 

Supersedes 3/2021

HEALTHY CLIMATE

® 

HEPA BYPASS AIR FILTRATION 

SYSTEM

INSTALLATION INSTRUCTIONS AND HOMEOWNER GUIDE FOR HEALTHY CLIMATE

®

 

MODELS HEPA-20, HEPA-40 and HEPA-60

WARNING

Improper installation, adjustment, alteration, ser vice or 

maintenance can cause property damage, personal injury 

or loss of life.
Installation and service must be performed by a li censed 

professional HVAC installer (or equivalent) or a service 

agency.

Rules for Safe Installation and Operation

Please read instructions before installing and using the 

HEPA Bypass Air Filtration System (HEPA system).  This 

will help you obtain the full benefit of the HEPA system you 

have selected. It will also help you to avoid needless ser-

vice costs.

1. 

Read this manual carefully.  Failure to follow these rules 

and instructions could cause a malfunction of air filter 

or unsatisfactory service and could void your warranty.

2. 

Follow a regular service and maintenance schedule 

to ensure efficient operation.

3. 

 For safety and optimized performance of your HEPA 

system, all installation and maintenance must be 

performed by a Healthy Climate

®

 dealer. The installer 

should be made aware of your indoor air quality 

situation and be familiar with your heating, ventilation 

and air conditioning equipment.

4. 

Remove HEPA cartridge packing materials before initial 

start-up of this product.

a. 

Remove  safety  screws  from  HEPA  filter  access 

panel.

b. 

Unlatch the four retaining clips and lift off HEPA filter 

access panel.

c.  Remove and discard the cardboard packing material 

between  the  HEPA  cartridge  and  the  filter  access 

panel.

d.  Ensure HEPA cartridge is installed and locked into 

place (brace the unit, press HEPA cartridge down 

and turn it clockwise to lock it into place.)

e. 

Replace  the  HEPA  filter  access  panel  and  latch  it 

with the four retaining clips.

f. 

Re-install  safety  screws  into  HEPA  filter  access 

panel.

5. 

 High particulate distribution may occur during initial  

start-up of this product after installation or after 

scheduled  filter  changes. 

Individuals who are highly 

sensitive to airborne particulates should not be in the 

building and allow 24 hours of operation for removal of 

particulates from occupied spaces before re-entry.

Shipping and Packing List

Package 1 of 1 contains:
1 - HEPA System
1 - Complete Filter Set (Packed inside Unit)

1 - Warranty Certificate

1 - Installation Instructions (this manual)

HEPA System Models

HEPA-20 (X4912)  is designed to filter air up to a rate of 

180 cfm

HEPA-40 (X4913)  is designed to filter air up to a rate of 

320 cfm

HEPA-60 (X4914)  is designed to filter air up to a rate of 

660 cfm

WARNING

Improper installation, adjustment, alteration, ser vice or 

maintenance can cause property damage, personal injury 

or loss of life.
Installation and service must be performed by a li censed 

professional HVAC installer (or equivalent) or a service 

agency.

WARNING

Electric Shock Hazard. Can cause injury or death. Unit 

must be rounded in accordance with national and local 

codes.
Line voltage is present at all components when unit is 

not in operation. Disconnect all remote electric power 

supplies before opening access panel. Unit may have 

multiple power sources.

WARNING

Risk of Carbon Monoxide Poisoning.
Can cause injury or death.
Do not operate equipment without access panel in place. 

Operation of this equipment without all access panels in 

place may cause gas fumes from the heating system to 

be drawn into occupied spaces.

Summary of Contents for HEPA Bypass Air Filtration Systems HEPA-20

Page 1: ...nel d Ensure HEPA cartridge is installed and locked into place brace the unit press HEPA cartridge down and turn it clockwise to lock it into place e Replace the HEPA filter access panel and latch it...

Page 2: ...s HEPA HEPA filter media is 99 97 efficient at capturing particles which are 0 3 micron in size or larger Inner Charcoal Filter Carbon Canister Carbon media is used to capture chemicals and odors also...

Page 3: ...l Retaining Clips 4 Inlet Collar Cabinet Outlet Collar On Off Switch Motor Section Access Panel Figure 1 Cabinet Parts HEPA Filter STAGE 2 Carbon Pre Filter STAGE 1 HEPA Filter Mesh Protects HEPA Filt...

Page 4: ...n during filter replacement Filter Change Schedule NOTE Failure to properly maintain your HEPA system will decrease the efficiency and air flow For enhanced odor control the Coconut Shell Carbon Can i...

Page 5: ...er making sure that the ends overlap d Hook one end of the clip onto the overlapping section of carbon pre filter as shown in figure 13 e Press down on the hooked section while you pull it across stre...

Page 6: ...let and turn it on Dealer Motor Assembly Replacement Instructions 1 Accessing the motor assembly a Turn the unit off and unplug it from any electrical source before opening the cabinet b To remove the...

Page 7: ...nd equipment to keep unit secure 2 Inlet Marked as Air In on unit Inlet ducts should be installed upstream of any hu midifiers and be installed on the main return Inlet duct should be installed at lea...

Page 8: ...that you have the proper chains straps joists and equipment to keep unit secure 2 Inlet Marked as Air In on unit Most HRV ERV systems will not move as much air as the HEPA system For these systems ins...

Page 9: ...d be installed at least 8 ft away from the outlet duct on the main return Inlet duct should be installed at opposite end of the room from the outlet duct s if in the same room Diffusers are recommende...

Page 10: ...2X17 92X10 92X10 Carbon Pre Filter X4137 X4138 X4138 Inner Charcoal Filter X2678 92X09 92X09 Carbon Canister 94X98 98X75 98X75 Optional Blower Interlock 24V relay X2680 X2680 X2680 Usethisunitonlyinth...

Reviews: