FEATURES

CONTROLS

Humidistat − HCWB2−12, HCWBK2−12 and HCWB2−17

Horizontal or vertical mount on wall or in duct
Provides manual control of room relative humidity.
Wired in series with the humidifier water solenoid valve.
Adjustable setting.

Universal Humidifier Control − HCWB2−12A,
HCWBK2−12A, HCWB2−17A, and HCWBK2−17A

Wall or duct mounted.
Automatic or manual control
Senses indoor relative humidity and outdoor temperature.
Includes outdoor temperature sensor for use with
automatic control option.
Adjusts humidity setpoint to provide optimum humidity
levels within the space.
Adjustable setting.

INSTALLATION KIT (HCWBK2 MODELS ONLY)

For Canada Only
Included with HCWBK2 models.
Kit contains: 6 in. dia. duct ring flange, 2.5 ft. of 6 in. dia.
galavanized steel flexible duct, 10 ft. of 1/4 in. OD
polyethylene water feed tube,  15 ft. of 1/2 in. ID clear
nylon drain tube, 10 ft. of 2−conductor 18 AWG thermostat
wire, one hose clamp, two plastic compression sleeves,
and two plastic compression ferrules.

MAINTENANCE SUPPLIES

Replacement Media

Recommended annual replacement of media pad.
See Specifications table for catalog number.

Water Supply

Consists of copper tube assembly with orifice,
cleanable/replaceable internal mesh strainer, distribution
tray and 24 volt brass water solenoid valve with stainless
steel seat.

Drain

1/2 in. drain fitting at bottom of cabinet.
1/2 in. ID plastic tubing must be field provided for models
without Installation Kit.
Unused water from the evaporator pad is drained from the
unit to help remove mineral deposits left from the
evaporative process.

Equaflo

t

 Distribution Tray

Deep reservoir and unique channel design provides even
water distribution across the evaporator media pad for
optimal performance.

Evaporator Media Pad

Provides large evaporation capacity.
Pad and support frame removable for cleaning or
replacement.
Annual pad replacement recommended.

Saddle Valve

All necessary fittings furnished as standard equipment.
Field installs in the water supply line.

SPECIFICATIONS

Model Nos.

Humidistat Control

HCWB2-12

HCWB2-17

with Installation Kit

HCWBK2-12

− − −

Universal Humidifier Control

HCWB2−12A

HCWB2−17A

Universal Humidifier Control and Installation Kit

HCWBK2−12A

HCWBK2−17A

Capacity

 − 120°F plenum temperature, 0.20 in. w.c. static

pressure drop

12 US gallons per day

16.75 US gallons per day

Water Feed Rate

3 gallons per hour

3 gallons per hour

Evaporator pad size

 − H x W x D − in.

9−7/8 x 9−5/8 x 1−5/8

13 x 10 x 1−5/8

Connections

Plenum H x W − in.

10 x 9−1/2

13−1/2 x 9−1/2

By−Pass Duct  − in.

6 round

6 round

Water supply

1/4 in. compression

1/4 in. compression

Drain

1/2 in. I.D.

1/2 in. I.D.

Electrical characteristics

24V

24V

Shipping Data − 

lbs. (1 package)

10

11

MAINTENANCE SUPPLIES − MUST BE ORDERED EXTRA

Replacement Media

X2660

X2661

Canada Only

Summary of Contents for HCWB2

Page 1: ...own flow applications See Typical Applications Provides additional humidity to the home during the heating season to increase comfort level Humidifier saddle valve and humidistat universal humidifier control shipped in one package Approvals Units are ETL listed per ANSI UL 998 and CSA C22 2 No 104 01 Sequence of Operation Humidifier will only operate when indoor blower is operating When the level ...

Page 2: ...e with stainless steel seat Drain 1 2 in drain fitting at bottom of cabinet 1 2 in ID plastic tubing must be field provided for models without Installation Kit Unused water from the evaporator pad is drained from the unit to help remove mineral deposits left from the evaporative process Equaflot Distribution Tray Deep reservoir and unique channel design provides even water distribution across the ...

Page 3: ...w direction is dependent on application For up flow horizontal applications air flow is from the humidifer to return air duct For down flow applications air flow is to the humidifier from the supply air duct 1 Left hand air inlet outlet shown For right hand inlet outlet rotate humidifier cabinet 180º top for bottom and relocate solenoid valve and drain to alternate location on cabinet See Installa...

Page 4: ...ormation www lennoxdavenet com Contact us at 1 800 4 LENNOX NOTE Due to an ongoing committment to quality Specifications Ratings and Dimensions subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause property damage or personal injury Installation and service must be performed by a qualified installer and servici...

Reviews: