 2 

Safety Reminder

                

 

To protect the device and operating personnel from electrostatic discharge, you need to check 
and ensure that the device is grounding well before the device is powered on. Please observe 
the following when you install, use, maintain this equipment.  

 

Make sure the device ground connection.

 

Disposal Instruction (US) 

 

For better protection of our earth, please don't throw this electronic device into municipal 
trash bin when discarding. 

 

To minimize pollution and ensure utmost protection of the global environment, please recycle 
the product. For more   
information about the collection and recycling of Waste Electrical and Electronic Equipment 
(WEEE), please contact your local dealers.  

Safety Instructions 

1.

 

Please read these safety instructions carefully. 

2.

 

Please keep this User Manual for later reference. 

3.

 

Please disconnect this equipment from connecter before cleaning. Don

t use liquid or 

prayed detergent for cleaning. Use moisture sheet or cloth for cleaning. 
4.

 

Make sure the equipment is connected to the power source with the correct voltage, 

frequency, and ampere. 
5.

 

All cautions and warnings on the equipment should be noted. 

6.

 

Never pour any liquid into opening, this could cause fire or electrical shock. 

7.

 

Never open the equipment. For safety reason, the equipment should only be opened by 

qualified service personnel. 
8.

 

If one of the following situations arises, get the equipment checked by a service personnel : 

a.

 

Liquid has penetrated into the equipment. 

b.

 

The equipment has been exposed to moisture. 

c.

 

The equipment has not work well or you can not get it work according to user

s manual. 

d.

 

The equipment has dropped and damaged. 

e.

 

If the equipment has obvious sign of breakage. 

9.

 

Ambient operation temperature: 0 ~ 45 degrees. 

10.

 

Risk of overheating! Don

t put operating/installing equipment inside too closed space, be 

sure the installation space at least 1 to 2 inches or 2 to 5 cm of space for ventilation. To ensure 
that other objects do not cover the equipment.   
 

Notice: Peripheral devices 

Only peripherals (input/output devices, terminals, player, etc.) certified to comply with Class B 
limits may be attached to this equipment. Operation with non-certified peripherals is likely to 
result in interference to radio and TV reception. 

Caution 

Changes or modifications not expressly approved by the manufacturer could void the user

authority,  which  is  granted  by  the  Federal  Communications  Commission,  to  operate  this 
equipment. 

 

 
 

Summary of Contents for FIX1818E

Page 1: ...1 FIX1818E 4K30 HDMI1 4 18x18 fixed HDMI Matrix Switcher Version V20 001 User Manual ...

Page 2: ...quipment should be noted 6 Never pour any liquid into opening this could cause fire or electrical shock 7 Never open the equipment For safety reason the equipment should only be opened by qualified service personnel 8 If one of the following situations arises get the equipment checked by a service personnel a Liquid has penetrated into the equipment b The equipment has been exposed to moisture c T...

Page 3: ...t Panel Switching Operation 7 6 1 1 Switch 7 6 1 2 Scene 7 6 1 3 Set Up 8 6 1 4 View 8 6 2 WEB Control 8 6 2 1 Login 8 6 2 2 Switch 8 6 2 3 Scene 9 6 2 4 Caption 7 6 2 5 Manager Control 10 6 2 6 Set Up 8 6 2 7 Upgrade 9 6 3 APP Control 8 6 4 COM Control Commands 11 7 Trouble Shooting and Attention 12 8 After Sales 12 8 1 Warranty 12 8 2 limitation and Exception 12 ...

Page 4: ...lso has optional Control4 Elan Drivers 2 Features Resolution up to 4K2K30Hz 3D 60Hz Supports 18 HDMI inputs with EDID key buttons and 18 HDMI outputs Support IOS Android APP RS232 and WEB GUI control and management Two key control method enabling easier and more effective controlling All front buttons with background light easier for switching status recognition Opening Web control codes enabling ...

Page 5: ...ard and short cut button for canceling to ALL outputs RECALL For recalling the saved scene E LCD SCREEN Operation information real time Display F NETWORK Flashing while using the WEB control operation G OUTPUT Output buttons with background light from 1 9 input buttons NO Name Function A RS232 1 RS232 male control port for the 3rd party control or sending RS232 commands B RS232 2 RS232 female cont...

Page 6: ...ENE interface Enter the wanted scene save number 1 9 then press SAVE If want to reload the saved scene press the scene number and press RECALL button 6 1 3 Setup Operation First press MENU switch to SETUP interface then continue next operation Via SETUP it can realize IP address changing in SETUP interface can use UP DOWN button to position enter the needed IP address from the left button side the...

Page 7: ...all the outputs Close one input to all the outputs Switch all inputs on all outputs Close all inputs to all outputs Switch to the scenes Save and Recall interface 6 2 3 Scene Scene Interface It can support 40 scenes in total users can preview each scene switching status by clicking on any of the scene number Click Save to save the switching status and Load to recall the scenes Back to return back ...

Page 8: ...input output and the scenes names have changed once click to the Switch and Scenes interface With this renaming function it can be easier for the users to know the sources and ends 6 2 5 Setup Setup interface Users can reboot change the IP address set up the login user names language and the RS232 baud rate settings here After changed the IP address will need to reboot the matrix switcher then the...

Page 9: ...ering team to have the technical support 6 2 7 Manager This Manager interface it allows the users to manage at most 254 units of the matrices which are installed at the same area network and at the same gateway but different IP addresses As below are showing 3 matrices users can rename each matrix and click button to do the switching or open in a new manage window 6 3 APP Control The matrix switch...

Page 10: ...n the MCS matrix control system APP and Enter the IP address of the matrix switcher the default IP addresses are 192 168 0 80 or 192 168 1 80 Step 2 After Enter the IP address it will need to login the default username and password both are the admin Step 3 After log in successfully users can do the same functions as the WEB GUI operation ...

Page 11: ...4 Z 1 2 3 4 Q 1 2 3 4 W 1 2 3 4 Switch Input Y to Output Z Q W Eg 1X2 3 4 means switch Input 1 to Output 2 3 4 SaveY Y 1 2 3 4 Save current status to scene Y Eg Save2 means saving current status to Scene 2 RecallY Y 1 2 3 4 Recall the saved scene Y Eg Recall2 means recall the saved Scene 2 BeepON Beep sound Buzzer on BeepOFF Buzzer off Y Y 1 2 3 4 Check the Input Y to outputs switching status Eg 1...

Page 12: ... product or component the delivery of the equivalent product or component to the user for replacement of the defective item or refund the payment which users have made The replaced product will become the property of the Company The replacement product could be new or repaired Whichever is longer any replacement or repaired of the product or component is for a period of ninety 90 days or the remai...

Reviews: