HDE DVI-100 Operating Instructions Manual Download Page 7

Kilo voltímetros medidores de alto voltaje alta tensión digitales DVI-100/K02 HD-ELECTRIC manual ingles www.viaindustrial.com

 

 

 

 

OTHER

 

ACCESSORIES

 

The

 

DVI-100

 

comes

 

standard

 

with

 

(1)

 

HP-DVI-2

 

small

 

overhead

 

hook

 

probe

 

and

 

a

 

CS-DVI

 

carrying

 

case.

 

The

 

DVI-500

 

comes

 

standard

 

with

 

(1)

 

HP-DVI-2

 

small

 

overhead

 

hook

 

probe,

 

(1)

 

HP-DVI-6

 

large

 

overhead

 

hook

 

probe

 

and

 

a

 

CS-DVI-5

 

carrying

 

case.

 

Both

 

cases

 

can

 

accommodate

 

the

 

IEP-DVI-5

 

underground

 

bushing

 

probe,

 

the

 

PT-DVI

 

Proof

 

Tester

 

and

 

a

 

spare

 

9V

 

battery.

 

 

ADAPTER

 

FOR

 

SHOTGUN

 

STICK

 

HSA

 

2500

 

 

HOTSTICKS

 

A

 

range

 

of

 

hotsticks

 

are

 

available

 

in

 

lengths

 

starting

 

at

 

4’.

 

Contact

 

HD

 

Electric

 

for

 

more

 

details.

 

 

SPECIFICATIONS

 

MODEL

 

NUMBER:

 

DVI-100,

 

DVI-100T,

 

DVI-500

 

and

 

DVI-500T

 

HP-DVI-6

 

 
 
 
 
 
 
 

HSA-2500

 

HP-DVI-2

 

 

OPERATING

 

VOLTAGE

 

DVI-100:

 

0

 

-

 

99kV

 

(0.1kV

 

-

 

9.9kV

 

and

 

10kV

 

-

 

99kV)

 

RANGES:

 

DVI-500:

 

0

 

-

 

500kV

 

(0.1kV

 

-

 

9.9kV

 

and

 

10kV

 

-

 

500kV)

 

OPERATING

 

FREQUENCY:

 

60Hz

 

(50Hz

 

available)

 

OPERATING

 

TEMPERATURE

 

RANGE:

 

-40F

 

to

 

+120F

 

(-40°

 

to

 

49°C)

 

DIMENSIONS:

 

Display

 

housing:

 

4.25”H

 

x

 

7”W

 

x

 

4.5”D

 

(11

 

cm

 

x

 

18

 

cm

 

x

 

11

 

cm)

 

Overhead

 

probes:

 

HP-DVI-2:

 

8”long

 

(20

 

cm)

 

for

 

conductors

 

to

 

1”diameter

 

HP-DVI-6:

 

12”long

 

(30

 

cm)

 

for

 

conductors

 

to

 

6”diameter

 

WEIGHT:

 

1.37

 

lb.

 

(0.62

 

kg)

 

with

 

overhead

 

probe

 

LED

 

HEIGHT:

 

DVI-100:

 

2.25”(6

 

cm)

 

DVI-500:

 

1.45”(3.7

 

cm)

 

ACCURACY:

 

Laboratory

 

calibrated

 

to

 

+/-

 

3%

 

Typical

 

overhead

 

line

 

in

 

compact

 

overhead

 

three

 

phase

 

+/-

 

10%

 

Other

 

applications

 

up

 

to

 

+/-

 

25%

 

BATTERY

 

LIFE:

 

About

 

100

 

readings

 

with

 

9V

 

alkaline

 

 

MAINTENANCE

 

AND

 

CARE

 

STORAGE

 

It

 

is

 

recommended

 

for

 

protection

 

of

 

the

 

DVI

 

that

 

it

 

and

 

its

 

accessories

 

are

 

stored

 

in

 

the

 

carrying

 

case

 

provided.

 

CLEANLINESS

 

The

 

molded

 

housing

 

is

 

very

 

rugged,

 

but

 

it

 

should

 

be

 

kept

 

clean

 

and

 

free

 

of

 

dirt,

 

grease

 

and

 

any

 

other

 

foreign

 

materials.

 

If

 

the

 

housing

 

surface

 

integrity

 

has

 

been

 

compromised

 

in

 

any

 

way,

 

remove

 

from

 

service

 

and

 

return

 

to

 

factory

 

for

 

repair

 

or

 

replacement.

 

DAMAGE

 

If

 

you

 

suspect

 

any

 

mechanical

 

or

 

electrical

 

damage,

 

do

 

not

 

use

 

the

 

DVI

 

and

 

arrange

 

for

 

repair

 

by

 

returning

 

to

 

the

 

factory.

 

CALIBRATION

 

&

 

TESTING

 

Regular

 

calibration

 

of

 

the

 

DVI

 

is

 

not

 

required.

 

There

 

is

 

no

 

accessible

 

calibration

 

adjustment.

 

SERVICE

 

Return

 

to

 

HD

 

Electric

 

Company

 

for

 

service.

 

 

7

 

Summary of Contents for DVI-100

Page 1: ...metros medidores de alto voltaje alta tensión digitales DVI 100 K02 HD ELECTRIC manual ingles www viaindustrial com DIGITAL VOLTAGE INDICATORS a n d ACC E S SOR I E S Operating Instruction Manual DVI 100 DVI 500 ...

Page 2: ... 1kV 100 volts to 9 9kVand from 10kVto 99kVfor the DVI 100and to 500kVfor the DVI 500 Anaudible alarm beeps whenever the indicated voltage is0 1kVor higher There are two versions available of each model The DVI 100and DVI 500indicate voltage bydirectly contacting conductors on overhead and underground systems The DVI 100Tand DVI 500Twith TestPoint mode also indicate voltage on elbow test points An...

Page 3: ...igh voltage or grounded conductor to contact the instrument duringuse Keep the DVI housing freeand clearofallstructures at alltimes Bridgingthe DVI probe or housing fromline to ground or line to linemaycause a faultand arc TheDVI does not indicate voltages below 100volts Alwaysuse proper grounding procedures Azero Theseimportantlabelsare affixedtotheproducts Readandunderstand beforeproceeding DVI ...

Page 4: ...before and after each use such as the PT DVIProof Tester Apply the DVIprobe to the conductor to be tested making sure to make metal to metal contact All readings are in kV Voltages below 0 1kV 100V may indicate zero Azero voltage reading does not mean the line is dead or grounded Voltage in excess of 99kV line to ground for the DVI 100 and in excess of 500kV for the DVI 500 will cause the display ...

Page 5: ...higher voltage overbuild accessory hardware such as fuses or disconnects or for measurements made on points such as terminations or endpoints best accuracyiswith the DVI as far away as possible from other liveconductors or grounds awayfrom points or corners and facing the ground Fig 3 4 Expected overall accuracyis 25 For measurements made on grounded conductors keep the Fig 1 Fig 2 Fig 3 DVI as fa...

Page 6: ... where grounded orother liveconductors maybe in closeproximityto the conductor being tested Toassemble the IEP DVI 5probe on the DVI 1 Inspect the IEP DVI 5probe foranymechanical defects and make certain itisclean and dry 2 Screwthe IEP DVI 5into the DVI Makecertain itissnug byhand tightening but DONOTOVERTIGHTEN 3 Testthe fullyassembled DVI on a known voltage source such as the PT DVIProofTester ...

Page 7: ...Displayhousing 4 25 Hx7 Wx4 5 D 11 cm x18 cm x11 cm Overhead probes HP DVI 2 8 long 20 cm for conductors to 1 diameter HP DVI 6 12 long 30cm forconductors to 6 diameter WEIGHT 1 37 lb 0 62 kg with overhead probe LED HEIGHT DVI 100 2 25 6cm DVI 500 1 45 3 7cm ACCURACY Laboratory calibrated to 3 Typicaloverhead line in compact overhead three phase 10 Other applications up to 25 BATTERYLIFE About 100...

Page 8: ...using parts sourced froma varietyofmanufacturers Due to the rapidlychangingtechnologyenvironment partsmaybecomeobsolete unavailableovertime endoflife IntheeventthataProductcannotberepaired orreplacedduetounavailabilityofparts HDElectricCompanywillusecommerciallyreasonableeffortstoobtainsubstitutepartsorconductworkaround design but cannot guarantee itsabilityto do so Itemsnotfounddefectivewillberet...