H B X E C O - 0 5 5 0 G e o t h e r m a l C o n t r o l
V e r s i o n 2 . 0 0
Page 2
DIMENSIONS
TECHNICAL DATA & DIMENSIONS
TECHNICAL DATA
Specifications:
3 x Thermistor Input
(10K Ohm)
2 x Miscellaneous Input Signal
3 x Relay Outputs (240VAC 5Amps) Dry
Contacts
1 x 2Amp Dry Contact
Input: /- 10% 50/60Hz 15A Max
FCC ID: 2AHMR-ESP12S
Weight:
0.408Kg
Dimensions:
100mm W x 168mm H x 70mm
ETL Listings:
Meets CSA C22.2 No. 24
Meets UL Standard 873
ETL Control No. 3068143
Storage:
50°F to 104°F (10ºC to 40ºC)
ECO-0550
Central Processing Unit
Relays:
240VAC 5A Max
Input:
120VAC 15A Max
ENTER
ECO
Input
Signals (4)
Heat Pump
Outdoor
Sensor
120
VAC
Relay
Outputs (2)
Reversing
Valve
Tank
Sensor (2)
66 mm
(2.60 in)
(2.76 in)
70.19 mm
Side View
Front View
Rear View
Top View
188 mm
(7.40 in)
(6.57 in)
(4.76 in)
(3.94 in)
121 mm
167 mm
100 mm
Bottom View