Mechanical installation
PW29P
A03578_02_Y00_00
HBM: public
11
Maximum capacity
Thread
Min. property class
Tightening torque
100 … 250kg
M8
10.9
35N
⋅
m
500 … 1000kg
M12
10.9
110N
⋅
m
1)
Recommended value for the specified property class. Please comply with the screw
manufacturer's instructions with regard to screw dimensions
Set the overload stop during
installation and fix in position
with a screw locking adhesive
Connector plug
Direction of loading center of platform
Load application
Mounting
Spacing disc
Spacing disc
=
=
=
=
Fig. 4.1
Load application and installation
Important
Load must not be applied to the side where the cable connection is located, as
this would cause a force shunt.
Setting the overload stop
Type PW29P load cells are fitted with an adjustable overload stop. Set this
overload stop before starting up the load cell.