10
PW6C... Single point load cells
HBM
A2424-1.0 en/de/fr
3
Specifications
Type
PW6C...
Accuracy class
1)
C3, C3MR
Max. number of l. c. intervals (n
LC
)
3000
Max. capacity (E
max
)
2)
kg
3
5
10
15
20
30
40
Minimum LC verification in-
terval (v
min
),
(Accuracy class C3)
g
0.5
1
2
2
5
5
10
Temperature effect on zero
balance (TK
0
) (Accuracy
class C3)
% of C
n
/ 10 K
"
0.0233
"
0.0280
"
0.0280
"
0.0186
"
0.0350
"
0.0233
"
0.0350
Minimum LC verification in-
terval (v
min
),
(Accuracy class C3MR)
g
0.2
0.5
1
1
2
2
5
Minimum LC verification in-
terval (v
min
) (Accuracy class
C3MR)
% of C
n
/ 10 K
"
0.0093
"
0.014
0
"
0.0140
"
0.0093
"
0.014
0
"
0.009
3
"
0.0175
Max. platform size
mm
300 x 300
Sensitivity (C
n
)
mV/V
2.2
"
0.2 (Option 6: A = 2 mV/V
"
0.1 %)
Zero signal
mV/V
0
"
0.12
Temperature effect on sen-
sitivity (TK
C
)
3)
in the tem-
perature range
+20...+40
°
C [+68...+104
°
F]
−10...+20
°
C [+14...+68
°
F]
% of C
n
/ 10 K
"
0.0175
"
0.0117
Rel. reversibil. error (d
hy
)
3)
"
0.0166
Non-linearity (d
lin
)
3)
% of C
"
0.0166
Ratio of minimum dead
load output return (DR)
% of C
n
"
0.0245
Off-center load error
4)
"
0.0233
Input resistance (R
LC
)
Ω
300...500
Output resistance (R
0
)
Ω
300...500 (Option 6: A = 410
Ω
"
0.2
Ω)
Ref. excitation volt. (U
ref
)
V
5
Nom. range of excitation
voltage (B
U
)
V
1 ... 12
Isolation resistance (R
is
)
at 100 V
DC
G
Ω
> 2
Nominal (rated) range of
ambient temperature (B
T
)
−10 ... +40 [+14 ... +104]
Operating temperature
range (B
tu
)
°
C [
°
F]
−10 ... +50 [+14 ... +122]
Storage temperature
range (B
tl
)
−25 ... +70 [−13 ... +158]
1)
According to OIMLR60 with P
LC
= 0.7
2)
Max. eccentric load according to OIML R76
3)
The values for linearity deviation (d
lin
), relative reversibility error (d
hy
) and temperature effect on sensitivity (TK
C
)
are recommended values. The sum of these values remain within the cumulated error limit acc. to OIML R60.
4)
According to OIML R76.