Assembly Instructions M8100-EN 

 

M8100-EN   2018-03 

 

3/8

 

 

  

 

 

 

Fig. 4: Front side of the evaluation unit 

 

Fig. 5: Rear side of the evaluation unit 

6. 

Proceed as follows in order to attach the cover of the 
evaluation unit: 

  Connect the ribbon cable to the keyboard and attach the cover. 

  Attach screws (Label 1 

 Fig. 4). 

  Tighten screws (Label 2 

 Fig. 5). 

 

 

7.

 

Connect control cable to ext. flow rate meter Flow-5. 

 

8.

 

Reconnect mains plug and switch on main switch. 

 

 

9.

 

Switch the unit on with the 

 key. 

  

 

  

 

NOTICE! 

Software version SW51-1_1335 or higher is 
required for the printed circuit board DFM-51 
(acceptance date 1253 and later). If necessary 
perform a software-update (

 Thermo-5 operating 

instructions)  

     

 

1

2

Summary of Contents for T24693

Page 1: ...on for carrying outconversion work on the unit Procedure DANGER Danger to life caused by electric current Touching conductive parts causes a direct danger to life Therefore For all work on the electri...

Page 2: ...1 Front side of the evaluation unit Fig 2 Rear side of the evaluation unit 4 Proceed as follows in order to remove the cover of the evaluation unit Remove screws Label 1 Fig 1 Detach screws Label 2 F...

Page 3: ...o the keyboard and attach the cover Attach screws Label 1 Fig 4 Tighten screws Label 2 Fig 5 7 Connect control cable to ext flow rate meter Flow 5 8 Reconnect mains plug and switch on main switch 9 Sw...

Page 4: ...configuration 10 Proceed as follows to assemble the new printed circuit board DFM 51 A 9 Change to the next screen page with the key Configure ext flow rate meter information on the rating plate Selec...

Page 5: ...et corresponding parameter Flow rate ext 1 8 Calibration at Service Calibration Flow rate external 1 to 4 or Service Calibration Flow rate external 5 to 8 to ON The flow rate is calibrated automatical...

Page 6: ...fected e g A1 with the or buttons Set parameter Flow rate calibration at Service Calibration Flow rate to ON The flow rate is calibrated automatically Only in the case of water devices If present set...

Page 7: ...if necessary the temperature sensor With a constant deviation set parameter Sensor offset under Service Calibration Temperature With a linear deviation set parameter Sensor asc cor under Service Calib...

Page 8: ...M8100 EN 2018 03 8 8 Parts list Pos Description O ID Pcs 01 Flow rate measuring board DFM 51 T24693 1 02 Assembly instructions German M8100 DE 1 03 Assembly instructions English M8100 EN 1 04 Assembly...