background image

 

 

 

Assembly Instructions M8155-EN 

 

M8155-EN   2018-03 

 

2/5

 

 

  

 

1.

 

Proceed as follows in order to cool down the unit. 

  Display menu page 

Functions

  Select the function 

Cooling

 and activate with the 

 key. 

 The activated function is indicated with the 

 symbol. 

  

2.

 

Switch off master switch and disconnect from mains supply. 

 

 

3.

 

Remove the cover from the unit (see Instruction Manual 
Chapter Maintenance). 

  

 

 

Fig. 1.: Electric part HB200/230Z2B 

4. 

Proceed as follows in order to replace the DFM-53 (A 9): 

  Remove all the plug connections of DFM-53. 

  Remove 4 x screws (Label 1 

 Fig. 1) on the electric part 

  Remove the printed circuit board DFM-53 (A 9) from the electric 

part. 

  Take screws with spacer bolts on new printed circuit board 

DFM-53. 

  Attach new DFM-53 (A 9) in the electric part and fasten it with 

4x screws (Label 1 

 Fig. 1) . 

  Connect all the plug connectors to the DFM-53 (A 9). Unmarked 

ribbon cables are to be connected as follows: 

Thermo-5, single unit 

X 533 (DFM-53) 

 X106 (USR-51) 

X 534 (DFM-53) 

 X 21 (GIF-51) 

 

Thermo-5, Module unit 

X 533 (DFM-53) 

 X 80 (plug HB IN) 

X 534 (DFM-53) 

 X 21 (GIF-51) 

   

  

 

 

 

5.

 

Close the unit correctly again. 

 

 

6.

 

Reconnect mains plug and switch on main switch. 

  

 

  

 

NOTE! 

The unit will maybe perform an automatic software 
update. 

     

 

A 9

1

Reviews: