Assembly Instructions M8095-EN
M8095-EN 2020-09
13/13
12.
Check calibration pressure sensor
Parameter
System pressure actual value
resp.
Main line
pressure
under
Display \ Actual value
must be 0 bar ± 0,1.
If this is not the case, item calibration pressure sensor must be
repeated.
ATTENTION!
Risk of incorrect calibration!
False calibrations can lead to faults witch the unit.
Therefore:
– Check the calibrations.
13.
Check unit functions.
14.
Switch the unit off by press the
key.