The connection to the PLC is done according to the diagram above using a cable with a M12 Female 
connector. Stop start pin3 and Digital input for calibration pin5 is not relevant for the ice bank. 

 
 
 
 
 
Sensor configuration 

 
 
 
All HB-product sensors can be configured using a laptop and a “M12-USB” cable. The software can be 
downloaded freely on the HB products web page. The configuration data can be stored in the sensor and will 
be there until erased even without power connection—just like you store data on a memory stick. When you 
change a value/setting there will be put a check mark next to it and that indicates you have changed 
something and need to store the data in the sensor. 
 
  
  

 

 

  
 
 

Summary of Contents for HBIB

Page 1: ...andard M12 interface like other HB product sensors and is configured by the HB tool The product consists of a box and two steel wires which can be adjusted in length by cutting The sensor is based on the capacitive measurement principle and reacts on ice and water between the wires The sensor is based on the existing defrost sensor where the wire is mounted between the fins in an evaporator The HB...

Page 2: ...ymbol below is used to point out important safety instructions for the user It will always be found in places in the chapters where the information is relevant The safety instructions and the warnings in particular must always be read and adhered to CAUTION Refers to a possible limitation of functionality or risk in usage NOTE Contains important additional information about the product and provide...

Page 3: ...cable ties or similar all the way from the box to the end of the wire Loose wires will impact stability 3 The free end of the wires must be placed above water level to avoid short circuiting by the water Likewise it is important that the insulation is unbroken on the wires in the water 4 The connection between the box and a PLC can normally be installed with a standard unshielded cable If the EMC ...

Page 4: ...ensor configuration All HB product sensors can be configured using a laptop and a M12 USB cable The software can be downloaded freely on the HB products web page The configuration data can be stored in the sensor and will be there until erased even without power connection just like you store data on a memory stick When you change a value setting there will be put a check mark next to it and that ...

Page 5: ...7 Calculate 0 4 actual measurement and type that in the box called Zero calibration in pF 8 Calculate 0 6 actual measurement and type that in the box called SPAN calibration in pF 9 Click on the box called Send Zero Span values Now the sensor will send you a signal from 4 to 20 mA linear to the measurement from Zero to Zero SPAN in the case shown from 185 to 463 The ice thickness will now be linea...

Page 6: ...tions IEC 68 2 6 4g Certifications EMC Emission EN61000 3 2 EMC Immunity EN61000 4 2 Mechanical specifications Materials mechanical parts AISI304 wire Materials electronic parts Nylon insulation Cable entry PG9 M12 Sensor Repair Complaints are processed by HB Products dealers distributors Please consider their complaint procedures before returning the sensor Note All terminals are protected agains...

Reviews: