Label
Rad
Type
Exponential
Unit
uR,mR,R
Precision
1
Bounce
2
Bounce interval
2
Norm value
Background value
Increment
10
Jump Increment
100
Min Value
0
Max Value
1.0E8
4.2.5 Calculated Meter Edit
To Create a Calculated Meter Type:
1. From the main menu, select Edit Meters.
2. Select the appropriate meter set.
3. The calculated meter uses the value of another meter as it’s input, so you will need
to create at least one meter in this group that is “standard” or “exponential”.
4. Next, create the meter name for the calculated meter.
5. Give it a label.
6. From the Type dropdown, select “Calculated”.
7. In the Units, key in the appropriate units for the meter.
8. In the calculation box, key in the formula. When referencing the other meter (from
step 4), place the name of the other meter in curly brackets. (e.g. {Radiation}.
9. Save.
For example, the current Cs137 meter is a function of the Radiation meter.
The Cesium meter is set as:
Label
Cs137
Type
Calculated
Units
kCPM
Calculation
0.0012 * {Radiation}
15