Operation
Resistance measurement / Ω
Set the appropriate range using the selector switch. Connect the black test lead to the "
COM
"
jack and the red test lead to the "
V/Ω
" jack. Connect the test leads with the test object and
read off the measurement result from the display.
Measurement range
Resolution
Accuracy
600
Ω
0.1
Ω
±1.2 % + 5 digit
6 K
Ω
1
Ω
60 K
Ω
10
Ω
600 K
Ω
100
Ω
6 M
Ω
1 K
Ω
60 M
Ω
10 K
Ω
± 2.0 % + 10 digit
Overvoltage protection: 250 V RMS
Off-load voltage: 1.2 V
Diode test
Set the selector switch to "
/ ". Actuate the "
SEL
" button x 2. Connect the black test
lead with the "
COM
" jack and the red test lead with the "
V/Ω
" jack. Connect the test leads
with the test object (red test lead = anode, black test lead = cathode). The forward voltage
is displayed.
Measurement range
Resolution
Accuracy
1 mV
Forward voltage
Overvoltage protection: 250 V RMS
Off-load voltage: 3.2 V
Continuity test
Set to "
/ " using the selector switch. Actuate the "
SEL
" button. Connect the black test
lead to the "
COM
" jack and the red test lead to the "
V/Ω
" jack. Connect test leads to the test
circuit.
Measurement Function
The integrated buzzer signals continuity less than 50
Ω
Off-load voltage: 1.0 V
^
hazet.com •
]
Electrical energy may cause serious injuries!
Always wear personal protective equipment!