Hayward only guarantees the quality, performance and safety of its products when assembled with genuine Hayward manufactured parts.
Use of non genuine Hayward manufactured parts will void all warranty.
Page 7 of 14
TigerShark / TigerShark QC / TigerShark 2
Rev. B
The motor unit (13) and the power supply box (1) do not contain any parts that are of use to the user. If they are opened the
warranty automatically becomes
NULL AND VOID
.
TigerShark Quick Clean
1. For installation and normal use of TigerShark QC, please refer to the chapter on general use.
2. In order to select the normal cycle or the economy cycle, please follow the following instructions: on switching on, the
economy programme is automatically selected. The “Quick Clean” light, situated on the control box, then comes on. In
this mode, TigerShark will switch off automatically after 90 minutes.
3. In order to select the normal programme, please press the “Full Cycle” button. The light situated above the button comes
on and indicates that the normal programme is running. In this mode, TigerShark will switch off automatically after 4 hours.
If the economy mode is finished, you should switch off TigerShark and then switch it back on in order to select normal mode:
normal mode can be selected only during an economy cycle.
Warning : Robotic cleaner equipped with Foam :
First run : Remove plastic sleeve protecting the foams before using the cleaner.
Do not use sharp tools to remove this plastic sleeve in order to avoid foams deterioration.
Put the cleaner in the water to soak the foams as they must be wet, press the foams with both hands under water to speed
the process.
Repeat the above process before each use.
Maintenance :
1- Clean the cartridge of the filter after use, every time the cleaner is used:
Lay TigerShark on its side. Undo the fastenings of the bottom cover (6) (Figures 1c-1d) and remove the bottom cover
assembly (7) (Figure 1e)
Remove the filter cartridge. If your filter is in 3 parts (ref. RCX70100), remove each element and clean it thoroughly using a
hosepipe with a spray head so to remove all of the waste. Hold the elements as shown in Figure 1f to enable the waste to
fall off.
Wash the inside of the bottom cover.
Put the filter cartridge back (Figure 1g)
Fit the bottom cover and re-engage the fastenings.
2- Clean the moving parts frequently.
CAUTION:
unplug the power supply box before performing this cleaning operation.
Inspect the orifice of the pump to check that no waste or hair is obstructing the Venturi tube. It can be cleaned by removing the
tube (9) and by turning it (Figure 1h). Clean off all of the waste that has built up between the tracks (10) and the wheels (11).
Regularly inspect the cleaner and cable; do not use if damaged or if any rough edges are visible on the cleaner; this can
cause damage to the pool.
Storage:
When it is out of the water, lay TigerShark on its side in a dry and shady place at a temperature between 5°C and 46°C
(Figure 1i)
Maintenance for the cable:
After a while and with use, the cable can become twisted (like a telephone cord). To remedy this, wedge
the handle in the opposite diagonal position (Figure 1b). TigerShark will then turn in the pool in the opposite
direction and the cable will untwist itself. It is also possible to pull regularly on the cord in the sun in order
to solve the problem.
Above all, remember to reverse the position of the handle after use, every time the cleaner is used.