background image

 

 

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

 

 

7

3.6.

 

Electrical Specs 

Use copper conductors only.  For indoor & outdoor use. 
 

PUMP MODEL 

TOTAL HP 

RATED HP

VOLTAGE 

AMPS

SP2305X7 

0.95 

0.75

115 / 208-230 

10.0 / 6.0-5.0

SP2305X7EE 

0.95 

0.75

115 / 208-230 

9.2 / 4.7-4.6

SP2305X7EESP 

0.95 

0.75

115 / 208-230 

9.2 / 4.7-4.6

SP2307X10 

1.25 

1.00

115 / 208-230 

13.3 / 6.9-6.8

SP2307X102 

1.25 / 0.20 

1.00 / 0.16

230

6.1 / 2.1

SP2310X15 

1.65 

1.50

115 / 208-230 

16.5 / 9.2-8.5

SP2310X152 

1.65 / 0.27 

1.50 / 0.25

230

7.7 / 2.8

SP2315X20 

2.10 

2.00

115 / 208-230 

17.4 / 10.6-8.8

SP2315X202 

2.20 / 0.36 

2.00 / 0.33

230

10.0 / 3.0

3.7.

 

Voltage 

Voltage at pump MUST NOT be more than 10% above or below nameplate rated voltage, or components may 
overheat, causing overload tripping and reduced component life.  If voltage is less than 90% or more than 110% of 
rated voltage when pump is running at full load, consult the power company. 

3.8.

 

Grounding and Bonding 

1.

 

Install, ground, bond, and wire pump in accordance with local or national electrical code requirements. 

2.

 

Permanently ground pump.  Use green ground terminal provided under access plate; use size and type wire 
required by code.  Connect ground terminal to electrical service ground. 

3.

 

Bond pump to pool structure.  Bonding will connect all metal parts within and around the pool with a continuous 
wire.  Bonding reduces the risk of a current passing between bonded metal objects, which could potentially 
cause electrical shock if grounded or shorted.  Reference NEC codes for all wiring standards including, but not 
limited to, grounding, bonding and general wiring procedures. 

4.

 

Use a solid copper conductor, size 8 or larger.  Run wire from external bonding lug to reinforcing rod or mesh.  
Connect a No. 8 AWG (8.4 mm

2

) [No. 6 AWG (13.3 mm

2

) for Canada] solid copper bonding wire to the pressure 

wire connector provided on the motor housing and to all metal parts of swimming pool, spa, or hot tub, and to 
all electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of 
swimming pool, spa, or hot tub. 

3.9.

 

Wiring 

 

 

WARNING

 – All electrical wiring MUST conform to local codes, regulations and the National Electric 

Code (NEC).

 

Pump MUST be permanently connected to circuit.  If other lights or appliances are also on the same circuit, be sure 
to add their amp loads before calculating wire and circuit breaker sizes.  Use the load circuit breaker as the Master 
On-Off switch. 

 

WARNING

 

Risk of dangerous or fatal electrical shock

. Be sure that power to the motor 

circuit is off before working on wiring, wiring connections, or motor. Re-install the motor end cover and all 
other wiring covers before turning on the power.

 

To Wire a Single Speed, Single Voltage Motor 

1. Turn off power. 
2. Remove the motor end cover. 
3.

 

There are two terminals labeled L1 and L2. Attach the power leads to these terminals. Either wire may attach to 

either terminal. 
4.

 

Reinstall motor end cover.  

 

WARNING

 – If you do not use conduit when wiring motor, 

be sure 

to seal wire opening on end of motor 

to prevent dirt, bugs, etc., from entering. 

 

 

Summary of Contents for SP2305X7

Page 1: ...Installation and Wiring 5 Start up and Operation 9 Shaft Seal Replacement 10 Replacement Parts 13 Warrantee 15 Registration 16 Basic safety precautions should always be followed including the followi...

Page 2: ...onding 7 3 9 Wiring 7 4 Startup Operation 8 4 1 Prior to Start Up 8 4 2 Starting Priming the Pump 9 5 Maintenance 9 6 Storage Winterization 9 6 1 Storing Pump For Winterization 10 7 Shaft Seal Change...

Page 3: ...GENUI NS all instructio y and or death h are damaged s on outlet cover a suction outlet a mechanical b ed to a large po re applied direc n cracked mis y swimsuit ha al entrapment nt Hazards by a perso...

Page 4: ...e electrical equipment and have the problem corrected by a qualified service representative before using CAUTION HAYWARD pumps are intended for use with permanently installed pools and may be used wit...

Page 5: ...azard Motors operate at high temperatures and if they are not properly isolated from any flammable structures or foreign debris they can cause fires which may cause severe personal injury or death It...

Page 6: ...th one to two layers of tape Wind the tape clockwise as you face the open end of the fitting beginning at the end of the fitting The pump suction and outlet ports have molded in thread stops Do NOT at...

Page 7: ...cal shock if grounded or shorted Reference NEC codes for all wiring standards including but not limited to grounding bonding and general wiring procedures 4 Use a solid copper conductor size 8 or larg...

Page 8: ...ge plug set for 230 volts Voltage change plug set for 115 volts Fig 3 9 1 Fig 3 9 2 Note Large white arrow is for reference only 5 Reinstall motor end cover WARNING If you do not use conduit when wiri...

Page 9: ...arranty CAUTION Before removing strainer cover 1 STOP PUMP before proceeding 2 CLOSE VALVES in suction and outlet pipes 3 RELEASE ALL PRESSURE from pump and piping system using filter manual air relie...

Page 10: ...shaft seal replacement Only qualified personnel should attempt rotary seal replacement Contact your local authorized Hayward Dealer or service center if you have any questions See Parts Diagram Figur...

Page 11: ...y into the recess of the seal plate item 13 with the polished side of the ceramic facing out 9 Assemble the motor to the seal plate item 13 with the four 4 3 8 bolts item 14 Torque bolts to 100 in lbs...

Page 12: ...will face up Replace three 3 diffuser screws item 7 Torque screws to 20 in lbs 7 6 Replacing the Motor Assembly 13 Re attach motor end cover canopy by using the two 2 hex shaped screws Slide the motor...

Page 13: ...4 Housing Bolts Seal Plate Spacers Square Nuts 1 7 SPX2300Z3PAK3 Diffuser Screws 3 Pack 1 8 SX220Z2 Diffuser O Ring 1 9 SPX2300B Diffuser 1 10 SPX2700C Impeller for HP Max Rate Pump 1 SPX2700CSP Impe...

Page 14: ...rofessional open the pump and remove the debris Pump Won t Prime 1 Empty pump strainer housing Make sure the pump strainer housing is filled with water the cover o ring is clean Ensure the o ring is p...

Page 15: ...of this equipment Hayward Pool Products Inc warrants its pumps to be free from defects in materials and workmanship for a period of ONE 1 year from the date of purchase when used in single family res...

Page 16: ...clude me on all e mail communications regarding Hayward Equipment or promotions Mail to Hayward Pool Products 620 Division Street Elizabeth NJ 07207 Attn Warranty Dept Or REGISTER YOUR WARRANTY ON LIN...

Reviews: