background image

2019-2631 

2019-10-10 

 
 

 
 

 

Saline C

TM   

6.0 Salt Chlorine Generator 

 

CONTROLS BACTERIA AND ALGAE 

in 

Swimming Pool (and Spa) Waters 

 

COMMERCIAL 

 
 

A maximum of 283,000 L of water can be treated with 

Saline C

TM 

6.0 Salt Chlorine Generator 

 

Maximum output of hypochlorous acid equivalent to 2.268 kg 

of free available chlorine per day 

 
 

For swimming pools, a range of 1.0 - 3.0 ppm of free available chlorine must be maintained. 

 

For spas, a range of 3.0 - 5.0 ppm of free available chlorine must be maintained. 

 

KEEP OUT OF REACH OF CHILDREN 

 

READ THE LABEL AND OPERATING MANUAL BEFORE USING 

REGISTRATION NO. 30927  PEST CONTROL PRODUCTS ACT 

WARNING: Operating the Saline C

TM    

6.0 Salt Chlorine Generator 

without water flow through the cell can cause a buildup of flammable gases 

which can result in FIRE OR EXPLOSION. 

 

Do not use this device with bromide products. 

 

 

NOTICE TO USER: This pest control product is to be used only in accordance with the 

directions on the label. It is an offence under the 

Pest Control Products Act 

to use this 

product in a way that is inconsistent with the directions on the label.  

 

Hayward Commercial Pool Products

 

10101 Molecular  Drive, Suite  200

 

Rockville, MD.  20850

 

Phone: (800)  657-2287 

www.haywardcommercialpool.com

 

Summary of Contents for Saline C® 6.0

Page 1: ...F CHILDREN READ THE LABEL AND OPERATING MANUAL BEFORE USING REGISTRATION NO 30927 PEST CONTROL PRODUCTS ACT WARNING Operating the Saline C TM 6 0 Salt Chlorine Generator without water flow through the cell can cause a buildup of flammable gases which can result in FIRE OR EXPLOSION Do not use this device with bromide products NOTICE TO USER This pest control product is to be used only in accordanc...

Page 2: ...ION NO 30927 PEST CONTROL PRODUCTS ACT This electrode must only be used on this model of chlorine generating device READ THE LABEL AND REFER TO OWNER S MANUAL OF THE TM SALINE C 6 0 SALT CHLORINE GENERATOR BEFORE USING Hayward Commercial Pool Products 10101 Molecular Drive Suite 200 Rockville MD 20850 Phone 800 657 2287 ...

Page 3: ...2019 2631 2019 10 10 Saline C TM 6 0 Salt Chlorine Generator Owner s Manual ...

Page 4: ...ION 6 7 PREPARING YOUR WATER BEFORE INSTALLATION 8 9 SALT CHART FOR CORRECT MAINTENANCE 10 TOOLS AND PARTS REQUIRED FOR INSTALLATION 11 INSTALLING YOUR SYSTEM PLUMBING 12 13 ELECTRICAL 14 SPECIFICATIONS AND FUSE SIZING 15 STARTING THE SYSTEM 15 GENERAL OPERATION 16 MAINTENANCE AND CLEANING 17 ...

Page 5: ...F CHILDREN READ THE LABEL AND OPERATING MANUAL BEFORE USING REGISTRATION NO 30927 PEST CONTROL PRODUCTS ACT WARNING Operating the Saline C TM 6 0 Salt Chlorine Generator without water flow through the cell can cause a buildup of flammable gases which can result in FIRE OR EXPLOSION Do not use this device with bromide products NOTICE TO USER This pest control product is to be used only in accordanc...

Page 6: ... offer you the ultimate in swimming environments and give you years of trouble free operation This user s manual will explain in detail the operation of your new system as well as water chemistry guides warranty information and much more If at any time you need additional information on your system please feel free to contact us ...

Page 7: ...warranties of the titanium electrodes will not be honored if the system is operated in water temperatures lower than 15 C Hayward warranties of the titanium electrodes will not be honored if the system is operated in water where the salt concentration is lower than 3000 ppm During the warranty period the customer shall return the defective component freight prepaid accompanied by the original invo...

Page 8: ...ur Hayward system never operates when the pumps are off All boxes on your Hayward system contain high voltage components Never open any box while power is on WARNING Heavy pool and or spa usage and higher temperatures may require higher chlorine output to maintain proper free available chlorine residuals If additional chlorine is required due to heavy bather loads use granular or liquid chlorine s...

Page 9: ... be protected from destruction by sunlight by addition of stabilizer cyanuric acid NOTE FOR USE ON SPAS For proper sanitation spas must be completely drained periodically The number of days between COMPLETE DRAINAGE is equal to the volume of spa water in litres divided by 10 times the maximum number of daily spa users Refill spa with water and repeat DIRECTIONS FOR USE of the device HEALTH AND HYP...

Page 10: ...inuously until the salt has all dissolved You must never leave large amounts of salt on the surface of the pool as this may cause damage to the pool surface When you add the initial load of salt you will need to add additional chlorine as the salt will cause a chlorine demand Your pool water should be balanced in the following range before turning your Hayward system on Water balance parameters Sw...

Page 11: ... testers require frequent calibration to ensure accurate readings failure to calibrate the equipment will result in inaccurate readings How to Calculate volume of a pool For a rectangular shaped pool Length m x Width m x Average Depth m x 7 5 x 3 8 Litres of water For an oval or round shaped pool Average length m x Average Width m x Average Depth m x 5 9 x 3 8 Litres of water ...

Page 12: ...120 140 160 180 200 4400 6 60 120 180 240 300 360 420 480 540 600 4000 10 100 200 300 400 500 600 700 800 900 1000 3800 12 120 240 360 480 600 720 840 960 1080 1200 3500 15 150 300 450 600 750 900 1050 1200 1350 1500 3200 18 180 360 540 720 900 1080 1260 1440 1620 1800 3000 20 200 400 600 800 1000 1200 1400 1600 1800 2000 2700 23 230 460 690 920 1150 1380 1610 1840 2070 2300 2500 25 250 500 750 10...

Page 13: ...ty Additionally you will need the following items not included to complete the installation Polypropylene tubing Flex PVC tubing Wall anchors Disconnect box fuse box conduit wiring and related material to supply 220v to systems 220v systems only The following tools will be required to complete the installation Hand Tools Power Tools Set of sockets Drill Hammer Hammer Drill Screw Drivers Flat Phill...

Page 14: ...hlorine production and ultimately reducing flow to the point that the flow switch de activates the system 3 If you elect to use the bypass plumbing method 2 you will need to purchase a butterfly valve based on the size of the pipe you are using This can sometimes be cost prohibitive but the upside of this plumbing method is that you are sending filtered water through the cell which reduces the fre...

Page 15: ... CONTROLLER PRESENT THE OUTLET LINE THAT FEEDS THE CONTROLLER PROBES COULD BE CONNECTED TO THE RECTIFIER BYPASS MANIFOLD PLUMBING METHOD 2 NOTES THE RECTIFIER COOLING LINES MUST BE CONNECTED FROM THE SUCTION SIDE OF THE PUMP AND AFTER THE FILTER ALWAYS USE FILTERED WATER ALTERNATIVELY IF THERE IS A CONTROLLER PRESENT THE OUTLET LINE THAT FEEDS THE CONTROLLER PROBES COULD BE CONNECTED TO THE RECTIF...

Page 16: ...outlet As above the cord labeled ORP must be plugged into a controller or a 120v outlet Your Hayward system must be wired to the main pump power supply so that if the pump is shut down the power to your Hayward system is lost ELECTRICAL SPECIFICATIONS AND FUSE SIZING MODEL MAX PRIMARY AC AMPS SYSTEM INPUT VOLTAGE BREAKER REQUIRED TM Saline C 6 0 Salt Chlorine Generator 9 9 110 120v 20amp Fuse sizi...

Page 17: ...ller calls for it If you are running your system manually you will need to find the point at which you keep a satisfactory level of chlorine in the water It may take several days to find this point If your Hayward system is linked to an automatic controller remember that it will only work when the controller is in feed mode It is also a good idea to make sure that your controller is not set in pro...

Page 18: ...box 1 you will notice the amperage needle of the gauge on box 3 increases or decreases Higher amperage higher chlorine production Normal operating amps and volts for this model device are Saline C TM 6 0 Salt Chlorine Generator 25 amps 15v Water flow through the Hayward cell is critical Whether you plumbed your system in using the pressure drop or bypass method please ensure that you have at least...

Page 19: ...e calcium minerals will build up on the plates especially at the top of the cell This buildup needs to be cleaned by removing the cell from the housing and soaking it in a dilute muriatic solution 1 5 for about 10 15 minutes Reverse polarity systems will need to be cleaned every 3 6 months Warranties will not be honored if it is determined that the cell has not been cleaned regularly 1 Muriatic ac...

Reviews: