background image

  

Page 42  

Power-Flo II 

Rev. B

Pompe

Référence  

moteur

Puissance 

nominale

Voltage

Fréquence

Nb phase

Ampérage

Condensateur

Taille et réglage 

disjoncteur

Hauteur mano-

métrique à débit 

nul

Pump

Reference motor

Nominal power

Voltage

Frequency

Nb phase

Amperage

Capacitor

Size & switch 

adjustment

Table of 0 flow 

pressure heads

Bomba

Referencia 

motor

Potencia no-

minal

Voltaje

Frecuencia
Numero de 

fases

Amperaje

Condensador

Tamaño y regu-
lación disyuntor

Cuadro de las 

alturas mano-

métricas con 

flujo 0

Bomba

Referência 

motor

Potência no-

minal

Voltagem

Frequência
Numero de 

fases

Amperagem

Condensador

Dimensão e 

ajustamento 

disjuntor

Cuadro de 

alturas mono-

métricas com 

caudal 0

Pumpen

Motor referenz

Nennwert

Volt

Frequenz

Anzahl Phase

Stromstärke

Kondensator

Masse & Span-

nung

Manometrische 

förderhöhe bei 0 

leistung

Pomp

Motor

referentie

Nominaal

vermogen

Spanning

Frequentie

Aantal fasen

Stroomsterkte

Condensator

Vermogen en 

afstelling onder-

breker

Tabel van mano-
meterhoogten bij 

een debiet 0

Pompa

Tiferimento 

motore

potenza nomi-

nale

Voltaggio

Frequenza

numero fasi

Amperaggio

Condensatore

Potenza e rego-

lazione interrut-
tore automatico

Tabella delle 

altezze mano-

metriche ad 

erogazione 0

насос

Мотор

справки

Номинальная 

сила

Напряжение 

тока

Частота

Номер участка

ампераж

Конденсатор

переключите 

регулировку

давление

(подача = 0)

SP8102XE31

SP8102XE31C

SPX81018Z1C

380 W

230-240 V

50 Hz

1 Phase

1,6 A

16 µF, 450 V

(10 A)

1,6 A

10,7 M

SP8103XE61

SP8103XE61C

SPX81025Z1C

470 W

230-240 V

50 Hz

1 Phase

2,0 A

16 µF, 450 V

(10 A)

2,0 A

12,7 M

SP8105XE81

SP8105XE81C

SPX81037Z1C

610 W

230-240 V

50 Hz

1 Phase

2,6 A

18 µF, 450 V

(10 A)

2,6 A

14,1 M

SP8107XE111

SP8107XE111C

SPX81055Z1C

790 W

230-240 V

50 Hz

1 Phase

3,4 A

18 µF, 450 V

(10 A)

3,4 A

14,6 M

SP8110XE161

SP8110XE161C

SPX81075Z1C

920 W

230-240 V

50 Hz

1 Phase

4,0 A

18 µF, 450 V

(10 A)

4,0 A

15,7 M

SP8115XE221

SP8115XE221C

SPX81110Z1C

1110 W

230-240 V

50 Hz

1 Phase

4,8 A

30 µF, 450 V

(10 A)

4,8 A

16,8 M

Summary of Contents for POWER-FLO II Series

Page 1: ...SAVE THIS OWNER S MANUAL HAYWARD POOL EUROPE 1070 All e des Ch nes CS 20054 Saint Vulbas 01154 Lagnieu Cedex France CENTRIFUGAL PUMPS POWER FLO II OWNER S MANUAL...

Page 2: ...the power and current of the pump WARNING Read and follow all instructions in this owner s manual and on the equipment Failure to follow instructions can cause serious injury or death This document s...

Page 3: ...shock caused by a possible break in the electrical insulation Provide protection against short circuiting the definition of the rating will depend on the value indicated on the motor name plate Provi...

Page 4: ...rain plug s and store in strainer basket 2 Disconnect electrical wires and pipe connections and store pump in a dry well ventilated room Or as a minimum precaution Disconnect electrical wires Remove f...

Page 5: ...suction piping E Low flow Generally Check for 1 Clogged or restricted strainer or suction line undersized pool piping 2 Plugged or restricted discharge line of filter high discharge gauge reading 3 Ai...

Page 6: ...leistung Pomp Motor referentie Nominaal vermogen Spanning Frequentie Aantal fasen Stroomsterkte Condensator Vermogen en afstelling onder breker Tabel van mano meterhoogten bij een debiet 0 Pompa Tife...

Page 7: ...Page 43 Power Flo II Rev B 1 3 2 4 5 6 11 7 8 9 10 12 13 14 15 16 17 17...

Page 8: ...SPX1600Z2 SPX1600Z2 SPX1600Z2 SPX1600Z2 SPX1600Z2 SPX1600Z2 11 SPX8100E SPX8100E SPX8100E SPX8100E SPX8100E SPX8100E 12 6060XZ1 6060XZ1 6060XZ1 6060XZ1 6060XZ1 6060XZ1 13 SPX81018Z1C SPX81025Z1C SPX81...

Page 9: ...ded that they have been used exclusively with HAYWARD parts and components The warranty does not cover damage due to frost and to chemicals Any other costs transport labour etc are excluded from the w...

Page 10: ...uf keinerlei Weise ver ndert wurden und unter der Bedingung dass diese ausschlie lich mit Bau und Ersatzteilen von HAYWARD verwendet wurden Auf Frost und Chemikalien zur ckzuf hrende Sch den sind von...

Page 11: ...Doklad o prodeji mus b t p ilo en k jak koli reklamaci Tento doklad si proto pe liv uschovejte Z ruka HAYWARD se omezuje na v m nu nebo opravu podle sv ho v b ru vadn ch v robk kter byly pou v ny k p...

Page 12: ...Page 48 Power Flo II Rev B HAYWARD 2 HAYWARD HAYWARD HAYWARD HAYWARD...

Page 13: ...Hayward is a registered trademark of Hayward Industries Inc 2014 Hayward Industries Inc...

Reviews: