USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
13
turn the switch on, then back off, then wait between 11 and 14 seconds and turn the switch back on. When the lights come back on, they should enter
program #1, and be synchronized.
Programs
When in Universal ColorLogic mode (default), the Universal ColorLogic/CrystaLogic light has the capability to display 17 different programs; 10 fixed colors
and 7 color-changing shows. These programs are advanced using power-cycling (quickly powering the lights on, then off, then back on). The programs
are listed below:
1. Show-Voodoo Lounge
2. Fixed-Deep Blue Sea
3. Fixed-Royal Blue
4. Fixed-Afternoon Skies
5. Fixed-Aqua Green
6. Fixed-Emerald
7. Fixed-Cloud White
8. Fixed-Warm Red
9. Fixed-Flamingo
10. Fixed-Vivid Violet
11. Fixed-Sangria
12. Show-Twilight
13. Show-Tranquility
14. Show-Gemstone
15. Show-USA
16. Show-Mardi Gras
17. Show-Cool Cabaret
Refer to the included color card as a quick reference to the available programs.
Networking
Using a ColorLogic modem AQL-COLOR-MODHV and Coupler LKBUN1000, owners of Hayward Pro Logic PS pool/spa controllers can network their LS-
CUN11xxx and/or LPCUN11xxx Universal ColorLogic light(s) allowing them to fully control the color, speed, motion and brightness of preset light shows.
If the lights will be networked, refer to the AQL-COLOR-MODHV ColorLogic Network module for operation instructions.
Troubleshooting
If you have a problem with your Hayward Universal ColorLogic/CrystaLogic light, please try the following tips before calling for service:
PROBLEM: Light will not advance to the next program when it is power-cycled (turned “off” and then back “on”).
SOLUTION: Do not power-cycle the switch too rapidly. Leave it off for at least 1 second before turning it back on.
PROBLEM: Light goes to white whenever it is power-cycled (turned “off” and then back “on”).
SOLUTION: Be sure that you power-cycle the light for less than 10 seconds.
PROBLEM: Multiple lights are not correctly synchronized.
SOLUTION: Verify that the Universal ColorLogic/CrystaLogic light is in the proper mode (page 12). Follow the steps in these instructions to re-synchronize
the lights.
PROBLEM: Light will not come on.
SOLUTION: Check input power to transformer and then light. Check ground fault and reset if necessary.
PROBLEM: Light will not come on or light cycles on and off.
SOLUTION: Automatic thermal switch may be cycling due to excessive temperatures. Check pool or spa water temperature.
PROBLEM: Light does not function properly, or does not function at all.
SOLUTION: Verify that your pool/spa controller is not “dimming” the light.