Operation

Universal ColorLogic/CrystaLogic Light modes

The Hayward Universal ColorLogic/CrystaLogic light is designed to operate in one of four modes; Universal ColorLogic (default), ColorLogic 4.0, ColorLogic 

2.5 & earlier and Pentair SAM.  

Universal ColorLogic mode (default):

  The light is shipped in this mode.  Use this mode for new installations and for installations with other Universal 

ColorLogic/CrystaLogic lights. 

ColorLogic 4.0 mode:

 Use this mode when installing your new light in systems with ColorLogic 4.0 lights.  The Universal ColorLogic/CrystaLogic light will 

be “seen” as another ColorLogic 4.0 light and will operate in the same manner as the others.   

ColorLogic 2.5 & earlier mode:

 Use this mode when installing your new light in systems with ColorLogic 2.5 & below lights.  The Universal ColorLogic/

CrystaLogic light will be “seen” as another ColorLogic 2.5 & earlier light and will operate in the same manner as the others.  

Pentair SAM:

 Use this mode when installing your new light in systems with Pentair SAm

®

  or SAL

®

 lights.  The Universal ColorLogic/CrystaLogic light will 

be “seen” as another Pentair SAm

®

/SAL

®

 light and will operate in the same manner as the others. 

How to change modes:

1.  Turn on lights and then turn off for between 11-15 seconds.

2.  Turn on lights and then turn off for between 11-15 seconds.

3.  Turn on lights and then turn off for between 11-15 seconds.

4.  The light should blink one of 4 colors indicating which mode it is currently in.  Refer to the table below to determine which mode the Universal Color-

Logic/CrystaLogic is in.  Note that new lights are shipped from the factory in Universal ColorLogic mode (blinking red).

 

5.  To change modes, turn light off and back on.  The light will then advance to the next mode.  Continue this method until you arrive at the desired 

mode.   

6.  When the light is in the desired mode, remove power from the lights for at least one minute.

7.  The light will restart in the new mode the next time it is turned on. 

Operating the Universal ColorLogic/CrystaLogic Light

The Universal ColorLogic/CrystaLogic light is controlled through power-cycling: a method of changing light programs which requires no special controller 

or interface. To activate the light, simply turn on the switch. To deactivate the light, turn off the switch. To advance to the next light program (fixed color or 

color show), turn the switch off, then back on within 10 seconds. 

When the light has been off for over 60 seconds, and is first turned on, it will come on to white for 15 seconds for quick clear view of your pool, then go to 

the last fixed color or color show it was running. 

Light Synchronization

If your pool or spa has multiple Hayward Universal ColorLogic/CrystaLogic LED lights, they may be operated independently, or they can be easily synchro-

nized so they will all display the same colors and shows at the same time. For light synchronization, all lights must be wired to the same switch. Once 

installed, all lights should be automatically synchronized, however, if they get out of sync, they can be re-synchronized easily. To re-synchronize your lights, 

Summary of Contents for LPCUN11 Series

Page 1: ...aLogic TM Installation and Operation Manual LPCUS11xxx LPCUN11xxx LSCUS11xxx LSCUN11xxx LPLUS11xxx LSLUS11xxx LPWUS11xxx Contents Safety Instructions 2 Introduction 3 Installation 4 Replacement Parts 11 Operation 12 Troubleshooting 13 Warranty 14 Registration Card 15 LED Light Fixtures Pour obtenir le manuel de l usager en Francais consultez www hayward pool ca ...

Page 2: ...ny section of the manual The above safety warnings and the complete installation instructions in this manual have been read and fol lowed A SAFETY LISTED POOL SPA ISOLATION TRANSFORMER HAS BEEN USED TO SUPPLY 14 VOLTS TO THE FIXTURE The transformer output wiring HAS NOT been tied or shorted to ground The cord length has not been extended beyond the guidelines in this manual The cord jacket is not ...

Page 3: ...scent pool light The 12 volt Hayward Universal ColorLogic and CrystaLogic LED light emitting diode underwater lighting fixtures you have purchased are UL Listed to be installed in all Hayward or any other manufacturer s light fixture housing niche Installation of light and niche must be in accordance with Article 680 of the National Electrical Code NEC and any applicable local codes Ensure that yo...

Page 4: ...ructions for details When using Hayward or other trans formers that offer a 14v option we suggest that you always use the 14 volt tap Install Niche new installations NOTE For installation of Hayward niches see installation instructions provided with the unit The light fixture must be installed in or on a wall of the pool or spa with the top of the lens not less than 4 inches 10 cm below the normal...

Page 5: ... box transformer kits LTBUY11H65 can be used when in line transformers are desired Refer to page 9 for more information Junction boxes must be installed not less than 48 inches 1 22 m from the edge of the pool or spa Run conduit from the niche up to the junction box such that the junction box is not less than 8 inches 20 cm above the maximum pool or spa water level or not less than 4 inches 10 cm ...

Page 6: ... it in the LFGUY1000 niche To mount the light insert it into the niche with the mounting hole located at the 11 o clock position Twist the light fixture clockwise until it firmly locks The mounting hole should now be at the 12 o clock position Figure 2 Install the trim ring by positioning the HAYWARD logo at the 11 o clock position onto the light fixture Twist the trim ring clockwise until it firm...

Page 7: ...ating the outer trim ring counterclockwise until it detaches Note that the light comes with the removable Twist Lock Latch factory installed for mounting into a Hayward niche LTGUY1000 In most cases the latch will not interfere with other installations If you find that the latch prevents the installation in your niche remove it by pulling it off of the two pins With the trim ring removed coil up t...

Page 8: ...LY HAYWARD GENUINE REPLACEMENT PARTS 8 For some installations into Pentair niches the plastic spacer must be used For some installations into Sta Rite and SwimQuip niches the bottom tab may need to be removed ...

Page 9: ...nsformer Run conduit from the junction box to the low voltage transformer pool spa controller or switch box Snake 2 wires through the conduit from the junction box to the power supply If multiple lights are being installed run additional conduit wires from the junction box to the additional junction box es When wiring multiple lights to the same 12 volt source do not exceed the transformers s tota...

Page 10: ...rystaLogic LED light If more than one light is installed multiple junction box transformers must be used The LRBUY11M13 model can be used to power two lights Run conduit from the junction box transformer to the pool spa controller or switch box Snake 3 wires through the conduit Connect the ground wires to the ground terminal connections inside the junction box Use wire nuts to connect the field in...

Page 11: ...te network control over the installed Universal ColorLogic CrystaLogic light s using the Pro Logic Controller When using network control custom colors and custom light shows can be programmed for each or all lights An LKBUN1000 is required for each transformer in use and is designed to install into the Hayward LTBUY11300 300 Watt and Hayward Junction Box transformers Refer to the LKBUN1000 install...

Page 12: ...blink one of 4 colors indicating which mode it is currently in Refer to the table below to determine which mode the Universal Color Logic CrystaLogic is in Note that new lights are shipped from the factory in Universal ColorLogic mode blinking red 5 To change modes turn light off and back on The light will then advance to the next mode Continue this method until you arrive at the desired mode 6 Wh...

Page 13: ... control the color speed motion and brightness of preset light shows If the lights will be networked refer to the AQL COLOR MODHV ColorLogic Network module for operation instructions Troubleshooting If you have a problem with your Hayward Universal ColorLogic CrystaLogic light please try the following tips before calling for service PROBLEM Light will not advance to the next program when it is pow...

Page 14: ...ct the place of purchase or the nearest Hayward Authorized Service Center For assistance on your nearest Hayward Authorized Service Center please visit us at www hayward com Hayward shall not be responsible for cartage removal repair or installation labor or any other such costs incurred in obtaining warranty replacements or repair The Hayward Pool products warranty does not apply to components ma...

Page 15: ...NG Warranty Card Registration Register online at www haywardnet com Years Pool has been in service 1 year 1 3 4 5 6 10 11 15 15 Purchased from_____________________________ Builder Retailer Pool Service Internet Catalog Company Name_________________________________ Address_______________________________________ City____________________ State_____ Zip__________ Phone_________________________________...

Page 16: ... AT www hayward com Hayward is a registered trademark and ColorLogic and CrystaLogic are trademarks of Hayward Industries Inc 2012 Hayward Industries Inc All other trademarks not owned by Hayward are the property of their respective owners Hayward is not in any way affiliated with or endorsed by those third parties ...

Reviews: