6
24
"R..7, F..7, K..7, S..7 Spiroplan
®
W Gear Units" - Operating Instructions
Inspection and maintenance periods
6
Inspection / Maintenance
6.1
Inspection and maintenance periods
Table 8: Inspection and maintenance periods
6.2
Lubricant replacement schedule
03357AEN
Fig. 7: Oil change intervals for standard gear units under normal environmental conditions.
Change the oil more frequently when using special versions subject to more severe/ag-
gressive environmental conditions!
Time period
What to do?
→
Section
every 3000 machine hours
at least every six months
check oil
see section 6.3
depending on operating instructions
(
→
Fig. 7) at least every three years
change mineral oil
replace bearing (anti.-fr.) grease
depending on operating conditions
(
→
Fig. 7) at least every five years
change synthetic oil
replace bearing (anti-fr.) grease
R/RF 17/27 and Spiroplan
®
gear units are lubricated for life and require no maintenance
5000
10000
15000
20000
25000
30000
[h]
CLP PG
CLP HC
CLP
120
[°C]
110
100
90
80
70
0
Oper
at
ing hour
s
Oil bath steady-state temperature
Average value per type of lubricant at 70° C