2
2. SPECIFICATIONS
2.1 Performance Data of Swimming Pool Heat Pump Unit
*** REFRIGERANT: R410A
Unit
Model
HP50A1
HP70A1
Heating Capacity
kW
14.7
22.0
BTU/h
50,000
75,000
Heating Power Input
kW
2.68
4.2
Running Current
A
12
19
Power Supply
V/Hz
208-230V~/60Hz 208-230V~/60Hz
Compressor Quantity
1
1
Compressor(s)
Rotary
Rotary
Fan Quantity
1
1
Fan Power Input
W
120
120
Fan Rotate Speed
RPM
850
850
Fan Direction
Horizontal
Horizontal
Noise (at 1 meter)
dB(A)
54
56
Water Connection
inch
1.5
1.5
Water Flow Volume Imperial/US m
3
/h/gpm
4.5/20
6/26
Water Pressure Drop (max)
kPa/psi
10/1.5
12/1.5
Unit Net Dimensions (L/W/H)
mm/in
1049x400x652 /
41.3x15.7x25.7
1162x470x865 /
45.7x18.5x34
Unit Shipping Dimensions
(L/W/H)
mm
1130x470x680 /
44.5x18.5x26.8
1220x490x880 /
48x19.3x34.6
Net Weight/Shipping Weight
kg
58/71
106/123
Heating:
Ambient temp (DB/WB): 80ºF (26.7ºC) / 75.8ºF (24.3ºC)
Water temp (in/out): 80ºF (26.7ºC) / 92ºF (28ºC)
Summary of Contents for HP50A1
Page 2: ......
Page 8: ...5 3 INSTALLATION AND CONNECTION 3 1 Installation Illustration ...
Page 19: ...16 6 APPENDIX 6 1 Connection of PCB Illustration ...
Page 20: ...17 6 APPENDIX 6 2 Wiring Diagram HP50A1 ...
Page 22: ...19 6 APPENDIX 6 3 Exploded View and Spare Parts HP50A1 ...
Page 23: ...20 6 APPENDIX 6 3 Spare Parts List Spare Parts HP50A1 ...
Page 24: ...21 6 APPENDIX 6 3 Exploded View and Spare Parts HP70A1 ...
Page 25: ...22 6 APPENDIX 6 3 Spare Parts List Spare Parts HP70A1 ...
Page 26: ......
Page 27: ......