background image

 

10 

4.2.1 Tank Positioning 

Chalk lines are recommended for multiple tank installations and should be laid for positioning 
each tank. The shipping pallet for the filter also serves as an anchor bolt hole template(s) to 
aid in positioning the filter tank(s).  

Attention must be paid to the location and routing of the influent, effluent and waste line 
plumbing when planning the proper location of the filter system. The tanks must be level and 
parallel to each other or damage may occur to filter tanks, operating valves or connecting 
piping.  

Anchor bolts, nuts and flat washers can be purchased. Anchor bolts must be installed and 
secured to comply with the requirement of specific seismic zones. If the filter room floor is not 
level, shims must be used to level the tanks or the face piping plumbing connections may 
break or leak. 

Select one of the following appropriate assembly steps for your filter system: 

4.2.1.1 Positioning Single Tank 

Position the tank in the desired location, drill anchor bolt holes, and install anchor bolts, 
washers and nuts. Tighten nuts to secure filter system. 

4.2.1.2 Positioning Multiple Tanks 

Position the tank positioning templates along the chalk line. The templates, when butted 
together side by side, will ensure the proper alignment of filter tank to filter tank and tanks to 
face piping. 

The pallet 

template footprint is 6” larger than the filter tank.

 

If you are positioning the rear of the 

filter tank six (6”) inches away from the mechanical room wall, you must set the templates at 
the “C” dimension for proper anchor/ tank location (see figure 4-1). 

Summary of Contents for HCF302

Page 1: ...CO MMERC IAL SAN D FI LTE R MANU AL Models HCF302 HCF362 HCF363 Models HCF302T HCF342T HCF343T HCF343F HCF362T HCF363T HCF363F LITCF301 ...

Page 2: ...stallation Notes 4 2 Filter Installation 4 3 Installation of the Pressure Gauge 4 4 Removing the Filter Manway Cover 4 5 Re Installation of the Manway Cover 4 6 Testing of Filter 4 7 Installation of the Sand 5 Normal Operation 5 1 Filtration 5 2 Backwash 5 3 Close Isolate 6 Changing of the Sand 7 Winterizing 8 Graph of Filter Head Loss 9 Replacement Filter Parts List 10 Warranty 11 Product Registr...

Page 3: ...nt Failure to follow instructions can cause severe injury and or death WARNING This product should be installed and serviced only by qualified professionals CAUTION All electrical wiring MUST be in conformance with all applicable local codes regulations and the National Electrical Code NEC WARNING To reduce risk of injury do not permit children to use or climb on this product Closely supervise chi...

Page 4: ...m system flow rate shall not exceed the values shown in the Pipe Sizing Chart found on page 12 Never use pool or spa if any suction outlet component is damaged broken cracked missing or not securely attached Replace damaged broken cracked or not securely attached suction outlet components immediately In addition to two or more suction outlets per pump installed in accordance with latest APSP stand...

Page 5: ... could result in severe personal injury and or property damage WARNING Never operate or test the circulation system at more than 50 PSI maximum WARNING Failure to install according to defined instructions may result in severe personal injury or death WARNING ELECTROCUTION HAZARD High voltage electricity is present in the pool and spa equipment High voltage electricity can cause shock and electrocu...

Page 6: ...the sand the sand bed depth characteristics of the sand such as granular size density etc A most important parameter is the water filtration rate Other factors affecting the selection of a filter are the materials used for its construction the working temperature and the operating pressure 2 2 Hayward Filters Manufactured from proprietary resins and fiberglass they are virtually corrosion proof Th...

Page 7: ...each pump is brought together in a single manifold to the filters This will allow for greater flow rates for the backwash cycle Install a check valve ahead of filter inlet to prevent contaminants from draining back into the pool Install a check valve between filter and heater to prevent hot water from backing up into filter and damaging internal components Disposal of waste water must meet local s...

Page 8: ...PM Vertical Horizontal HCF302T 16 5 24 0 30 63 42 5 2 4 9 46 98 371 650 42 5 30 0 HCF342T 18 75 26 25 34 5 47 5 2 6 3 59 126 477 950 47 5 34 0 HCF343T 18 75 26 25 34 5 47 5 3 6 3 59 126 477 950 47 5 34 0 HCF343F 18 5 26 22 34 5 47 5 3 6 3 59 126 477 950 47 5 34 0 HCF362T 18 75 26 25 37 0 48 5 2 7 16 67 143 2 542 1050 48 5 36 25 HCF363T 18 75 26 25 37 0 48 5 3 7 16 67 143 2 542 1050 48 5 36 25 HCF3...

Page 9: ...leave a minimum access space around the filter s as defined on page 7 The equipment room should be well ventilated an provided with adequate drainage capabilities so that should an emergency occur resulting in flooding from a pipe filter or pump the water can be easily removed to avoid property damage If drainage cannot be supplied directly from the equipment room consideration should be given to ...

Page 10: ...ones If the filter room floor is not level shims must be used to level the tanks or the face piping plumbing connections may break or leak Select one of the following appropriate assembly steps for your filter system 4 2 1 1 Positioning Single Tank Position the tank in the desired location drill anchor bolt holes and install anchor bolts washers and nuts Tighten nuts to secure filter system 4 2 1 ...

Page 11: ...11 Figure4 1 AnchorTemplateDimensions FilterModel A B C HCF30 39 36 6 HCF34 42 40 6 HCF36 45 42 6 Position first tank installing all anchor bolts and secure before positioning the next tank and so on ...

Page 12: ... electrical power in the equipment controls 2 Set all system valves in a position to prevent water from flowing to the filter 3 The manual air bleed valve vent valve must be placed in the OPEN position 4 Wait until all water leakage has stopped 5 While holding the manway cover by the finger holes rotate the knob portion of the manway cover yoke counterclockwise until released from the manway cover...

Page 13: ...n the water from the filter after the testing sequence 4 7 Installation of the Sand WARNING After testing has been finished and the system is 100 operational add the filtration sand required Use 20 silica sand 45 55 mm Open the vent valve remove the manway cover and seal from the filter See section 4 4 page 9 Ensure the filter is full of water up to the inlet port The proper amount of sand is list...

Page 14: ... the pump set the valve s into the Backwash position and restart the pump The backwash cycle should be run for 3 to 5 minutes Once backwash is complete turn pump off and set valve s to the Filter position and start pump NOTICE It is very important to turn off the filter pump s prior to changing valve s position 6 Changing of the Sand The procedure for changing the filter sand is as follows 1 WARNI...

Page 15: ...0 8 0 10 0 12 0 14 0 16 0 0 30 60 90 120 150 Flow GPM Total Head Ft of Water HCF36 0 0 2 0 4 0 6 0 8 0 10 0 12 0 14 0 16 0 0 30 60 90 120 150 Flow GPM Total Head Ft of Water Figure8 1 AcceptablePipeSizeForMaximumRecommendedSystemFlowRate PipeSize FlowRateGPM PipeSize FlowRateGPM 2 63mm 90 340lpm 4 100mm 350 1325lpm 3 90mm 200 757lpm 6 150mm 800 3028lpm ...

Page 16: ...16 9 Replacement Part Drawing and Numbers Figure9 1 ...

Page 17: ...MWY1000 HCXFMWY1000 HCXFMWY1000 HCXFMWY1000 HCXFMWY1000 HCXFMWY1000 HCXFMWY1000 6 1 Distribution Manifold Assembly HCXFDHA1000 HCXFMWK1001 HCXFMWK1002 HCXFMWK1002 HCXFMWK1003 HCXFMWK1004 HCXFMWK1004 7 1 Internal Air Relief Assembly HCXFARA1000 HCXFARA1001 HCXFARA1001 HCXFARA1001 HCXFARA1002 HCXFARA1002 HCXFARA1002 8 1 Collector Manifold Assembly HCXFCMA1000 HCXFCMA1001 HCXFCMA1002 HCXFCMA1002 HCXF...

Page 18: ...e center near you No returns may be made directly to the factory without the express written authorization of Hayward Pool Products To original purchasers of this equipment Hayward Pool Products warrants its products to be free from defects in materials and workmanship for a period of FIVE 5 years from the date of purchase All other conditions and terms of the standard warranty apply Hayward shall...

Page 19: ...service 1 year ___ 1 3 ___ 4 5 ___ 6 10 ___ 11 15 ___ 15 ___ Purchased from_______________________________________________________________ _ Builder ___ Retailer ___ Pool Service ___ Internet Catalog ___ Company Name_______________________________________________________________ _ Address_____________________________________________________________________ _ City___________________________________...

Reviews: