Setting Heat Pumps for Remote Operation
Use Terminals 1 and 2
for 2 wire remote connection
Heat Pro Heat Pumps
For 2 wire remotes such as Hayward’s Pro-Logic, attach the 2 low voltage
wires from remote to terminals 1 and 2 on terminal block TB201. Set heat
pump to standby mode (three red dots scrolling across screen). Heat
pump is now ready for remote operation.
Heat Pro Heat Pumps
For 3 wire remotes where the desired temperature is set on the heat pump,
attach the 3 wires from your remote to the 3, 4 and 5 terminals on terminal
block TB201. Attach the pool wire to terminal 3, the common wire to
terminal 4 and the spa wire to terminal 5. Set both the pool and spa desired
temperature on the heat pump before turning on the remote. Once the
remote is calling for pool or spa you will not be able to change the function
on the heat pump without turning the remote off.
Use Terminals 3,4,& 5
for 3 wire remote connection
Note:
Heat Pro HP21404T, and HP50TA
are built on the Summit platform. For remote
connection see next page.