Start-Up & Operation  

New Installation/Seasonal Start-Up  

1. 

Close drain plug at the base of filter.  

2. 

Secure and lock Easy-Lok™ ring.  

3. 

Open air vent valve (Rotate the knob counterclockwise).  

4. 

Open valves (Optional suction & return valves). 

 

 

WARNING    COMPONENT SEPARATION HAZARD

  

Failure to open all suction and 

outlet valves can cause severe personal injury and/or property damage.  OPEN all suction 
and outlet valves before operating the filter system. 

5. 

Prime and start the pump per manufacturer’s instructions.  

6. 

Once air has escaped the filter and a steady stream of water is flowing from the air vent valve, 

close the air vent by turning clockwise and note the pressure gauge reading. 

Filter Disassembly & Assembly  

Cleaning/Removing Cartridge Element  

NOTICE: An indication that the filter needs cleaning is when the pressure gauge rises 5-7 
PSI above its starting pressure.  

1. 

Shut off the pump.  

2. 

Close valves* (*optional: suction & return valves).  

3. 

Open air vent valve.  

4. 

Open drain plug (located at the base of the filter body).  

5. 

Depress safety latch (located on the underside of the locking ring handles) and unscrew locking 
ring in a counter-clockwise direction.  Remove lid from filter body.  

6. 

Lift out filter element and clean as instructed in “Preventative Maintenance” section of this 
manual.  

Re-Installing Cartridge Element  

1. 

Clean debris from bottom of filter tank.  

2. 

Replace element evenly on the collector hub in bottom of the filter body.  

3. 

Place lid evenly on filter body and turn Easy-Lok™ ring clockwise until the safety latch engages 
securely.  

4. 

Close and secure drain plug (located at the base of filter body).  

5. 

Proceed as in “Start-Up & Operation”. 

Vacuuming  

Vacuuming can be performed directly into the filter whenever needed.  For fastest results, clean 
the filter before and after each vacuuming.  For heavy spring clean ups, we recommend using a 
Hayward SP0727 diverter valve to bypass the filter and accelerate the clean up process.  Consult 
your local Hayward dealer for a detailed explanation 

 

Winterization  

In areas where sub-freezing temperatures can be expected, the filter should be drained and/or 
removed from its operating location and stored indoors.  Clean the cartridge element at the end 
of the pool season by using the Hayward Jet-action Cleaning Wand (EC2024) or a garden hose. 
(See “Cleaning Cartridge Filter” instructions in this manual. 

 

 

Summary of Contents for EasyClear C550

Page 1: ...n ntial hazard tructions tha Haywar 0 Division Str Phone www GENUINE REPL Cle r s Ma XES C55 AFETY INS d including t his symbol o e potential fo use serious p n cause mino It can also t are importa d Pool Produ reet Elizabet 908 355 79 hayward co Con Warn Intro Insta Repl Warr LACEMENT PA ear anual 501575XE STRUCTIO the following on your equip or personal i personal inju or or moderat make consu a...

Page 2: ...th which are dam ment hazards on outlet cover a suction outlet a mechanical b ed to a large po re applied direc n cracked mis y swimsuit ha al entrapment ent Hazards by a person a m e i e floor or w int ocations and dis eating areas or ed 6 ft sec in th mponent is dam or not securely mp installed in al codes applica m which relieve plugs and or p or suction entra omponents cle on entrapment e a fi...

Page 3: ...the electrical equipment and have the problem corrected by a qualified service representative before using CAUTION HAYWARD pumps are intended for use with permanently installed pools and may be used with hot tubs and spas if so marked Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for stora...

Page 4: ...a ock replace da e equipment ock do NOT u fied personne per installatio rmance above years of troub access to all i ghtening of co ter to be remo oss due to ba ARD GENUIN cifically desig esign reduce or performan rmanently ins with storable adily disassem e and reassem vised to protec t requires free ding lug to rei provided on th al piping or co wire se of a cord NEC the follo ARD protected by a ...

Page 5: ...nough to prevent leakage Tighten fitting by hand and then use a tool to engage fitting an additional 1 turns Use care when using Teflon tape as friction is reduced considerably do NOT over tighten fitting or you may cause damage If leaks occur remove connector clean off old Teflon tape rewrap with one to two additional layers of Teflon tape and re install connector Use 1 I D flexible plastic pipe ...

Page 6: ...n the underside of the locking ring handles and unscrew locking ring in a counter clockwise direction Remove lid from filter body 6 Lift out filter element and clean as instructed in Preventative Maintenance section of this manual Re Installing Cartridge Element 1 Clean debris from bottom of filter tank 2 Replace element evenly on the collector hub in bottom of the filter body 3 Place lid evenly o...

Page 7: ... 9 Gaske 1 M Pump 5Z6 O ring 0WA 6 Ft Co 0WA1 3 Ft Tw 8A Moun washe Base tion Area ate rking Pressure rance acement idge placement idge USE ON NT PARTS DESCRIPTION ure Gauge nt Valve w O k Valve Ring Lid w Check V k Ring Lid O ring Ring Latch dge Element 4 Element 40 ft dge Element 5 Element 55 ft Lower Body 0 Lower Body Cap et Male Union g ord wist Lock Cord ting screw er Standard Easy C400 40 FT...

Page 8: ...t al damages of an mplied warranty ou specific legal r Clear is a trademar reserved ame_______ ___________ ate_________ Purchase Date ___________ ____________ s ve individual se or those indivi for the overall of the product arding Hayward on Street Eliz WWW HAYWAR completely and m Register onli RD GENUINE T REGISTRA For Your Record _________ rtion in a safe roducts Lim warrants its produ amily re...

Reviews: