Limited Warranty

Hayward Commercial Pool warrants the CAT 1000 automated controller to be free of defects in material and workmanship for a period 

of 5 years from the date of shipment from our factory or authorized distributors. Liability under this warranty is limited to the repair or 

replacement of any device or component which is returned to the factory within 5 years of delivery to the original purchaser, shipping 

pre-paid, and which is found to be defective upon examination.

Hayward Commercial Pool warrants all flow sensors, fittings and accessories to be free of defects in material and workmanship for a 

period of one year from date of shipment from our factory or authorized distributor.   Professional Series ORP sensors are warranted for a 

period of two years from date of shipment from our factory or authorized distributor. Liability under this warranty is limited to the repair or 

replacement of any device or component which is returned to the factory within the warranty period, shipping, and which is found to be 

defective upon examination. 

Hayward Commercial Pool disclaims all liability for damage during transportation, for consequential damage of whatever nature, for dam-

age due to handling, improper installation or operation, and for determining suitability for the use intended by the purchaser.  Hayward 

Commercial Pool makes no warranties, either expressed or implied other than those state above.  No representative has authority to change 

or modify this warranty in any respect.  After obtaining a Return Merchandise Authorization form, any warranty claims should be directed 

to the following address:

Hayward Commercial Pool  

10101 Molecular Drive Suite 200

Rockville, MD 20850 (USA)

Summary of Contents for CAT-1000-ORP

Page 1: ...ignored presents a potential hazard CAUTION warns about hazards that will or can cause minor or moderate personal injury and or property damage and if ignored presents a potential hazard It can also...

Page 2: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 2...

Page 3: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 3...

Page 4: ...ate pressure from the system Physically installation of a CAT controller is no more challenging than installation of a chemical feeder Any Swimming pool contractor or maintenance engineer should have...

Page 5: ...result in the sanitizer being used up pH is the most important factor in keeping the strength of your sanitizer The Potential of Hydrogen or Power of Hydrogen relates to HOCL and OCL If you have a lo...

Page 6: ...installation Drill Cordless Preferred 7 16 Drill Bit 1 4 NPT National Pipe Tapered Tap Masonry Drill Bit Anchors if required 13 16 Wrench or Channel Lock Pliers Installation Procedures The key to a su...

Page 7: ...er as labeled 11 Check all electrical and mechanical connections Resume filtration system operation and check for any leaks Preparing Water Chemistry Now that your new controller has been physically i...

Page 8: ...until the green MANUAL LED is illuminated The chemical feeder will operate continuously for 30 minutes and then automatically revert to Auto to prevent accidental over feeding Manually Disabling ORP F...

Page 9: ...t is turned off When the measured ORP value is less than the ORP setpoint the ORP feed output is turned on ON On Default The ORP feed output is activated based on the difference between the ORP setpoi...

Page 10: ...esume automatically when the measured ORP value returns to within the non alarm range 900 Use the UP and Down buttons to select a value between 400 and 995mV The value must be greater than the ORP ala...

Page 11: ...mical feeder is functioning properly and that an adequate chemi cal supply is available ORP Digital Display 3 The red digital numeric display of the ORP channel normally indicates the current ORP of t...

Page 12: ...Sensor Replacement CAT Professional Series ORP sensors are engineered to provide the highest performance and longest possible functional service life If a properly cleaned sensor provides unstable re...

Page 13: ...ion If sensors continue to provide unstable readings after cleaning replace sensors 3 Check to ensure that all electrical equipment in the facility pump room is properly bonded ORP chemical feeder run...

Page 14: ...nsors are warranted for a period of two years from date of shipment from our factory or authorized distributor Liability under this warranty is limited to the repair or replacement of any device or co...

Page 15: ...egister online at www haywardnet com Years Pool has been in service 1 year 1 3 4 5 6 10 11 15 15 Purchased from_____________________________ Builder Retailer Pool Service Internet Catalog Company Name...

Page 16: ...website at www haywardcommercialpool com Hayward CAT Controllers and CAT 1000 are registered trademarks of Hayward Industries Inc 2012 Hayward Industries Inc All other trademarks not owned by Hayward...