AUTOMATIC RESET TIME
:
The heater will automatically reset when an error condition is corrected and resume operation. The heater
can be manually reset using the keypad by cycling the MODE button through STANDBY and back to the
original operating mode (SPA or POOL).
PERIODIC INSPECTION:
The heater is designed and built for long performance life when installed and operated according to the
manufacturer’s directions. Regular inspection by quali
fi
ed service personnel is recommended to keep the
heater working properly. The following inspection points are suggested to help maximize heater life.
1. Periodically check the venting on outdoor heaters. The heater’s venting area (the box on the rear
of the heater) must never be obstructed in any way and minimum clearances must be observed to
prevent restriction of combustion and ventilation air. Remember that shrubs grow and in time may
obstruct a heater’s venting areas.
2. Keep the entire pool heater area clean and free of all debris, combustible materials, gasoline, and
other
fl
ammable vapors and liquids. Remove any leaves or paper from around the heater.
3. Do not store chlorine, other pool chemicals, or other corrosives in the vicinity of the heater.
4. If the heater is operating on propane gas, the tank must not fall below 30% full or damage to the
heater may occur. Hayward will not be responsible for heaters that soot up due to improper gas
level in the tank resulting in inadequate gas volume.
5. If another appliance is added to the gas line at a later date, consult the local gas company to be sure
the gas line will have the capacity to supply both units at full input rating at the same time.
6. Do not use the heater if any part has been under water. Contact a quali
fi
ed service technician to
inspect the entire heater and replace any part of the control system or gas valve that was under
water. If heater has been totally submerged in water it must be removed and the entire heater must
be replaced.
7. An inspection program is a good preventative maintenance measure. Keep this manual in a safe
place for future reference for yourself as well as for a service technician to consult when inspect-
ing or servicing the heater. Additional inspection procedures to be performed by a quali
fi
ed service
technician are covered in
Section IV of this manual.
WINTERIZATION:
In moderate climates, the heater can continue to operate during short-term cold spells. Do not use the
heater to maintain the water temperature just above freezing or for freeze protection. Care must be taken to
avoid freeze-up in the heater. When it is used during freezing weather, the pump must run continuously. The
heater is not warranted against freeze-ups. In regions where freezing temperatures are encountered, all water
must be drained from the heater when it is out of service, to prevent damage to the heater and piping. Drain-
ing the heat exchanger is recommended as part of the season’s shutdown procedures.
ATTENTION
: A heater damaged by freezing is not covered under the Hayward warranty.