background image

1301666601 rev B

Page 3 of 10

Ground Level

Ventilation 

Air

Combustion 

Air

A

ir 

D

uc

t f

ro

m

 

G

ro

un

to

 B

as

e

Drip Tee

Gas Cock

Sediment Trap

Level Flooring 

or Slab

Rise of 1 inch 

per foot

Vent Cap

Free Area per 

Btu 

Requirement

Total 

Input                                  

(btu/hr)

Combustion Air 

Free Area 

Required              

(sq. in.)

Ventilation Air 

Free Area 

Required                    

(sq. in.)

150,000

150

150

200,000

200

200

250,000

250

250

300,000

300

300

350,000

350

350

400,000

400

400

150,000

75

75

200,000

100

100

250,000

125

125

300,000

150

150

350,000

175

175

400,000

200

200

150,000

37.5

37.5

200,000

50

50

250,000

62.5

62.5

300,000

75

75

350,000

87.5

87.5

400,000

100

100

150,000

600

600

200,000

800

800

250,000

1000

1000

300,000

1200

1200

350,000

1400

1400

400,000

1600

1600

1 sq. in. per 

1,000 btu/hr               

(paragraph A)

1 sq. in. per 

2,000 btu/hr                     

(paragraph B-2)

1 sq. in. per 

4,000 btu/hr                       

(paragraph B-1)

1 sq. in. per 250 

btu/hr                       

(paragraph B-4)

TABLE 5

FIGURE 1

EN

G

LIS

H