background image

AQLTCHLOR Rev A

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT 

PARTS 

    

6

 

 

 

                             

SPARE PARTS: 

Tank Cap  GLX-LFCAPY 

YELLOW 

 

 

 

 

Check Valve 

CAX-3511 

 

 

PART NUMBER 

DESCRIPTION 

NO. REQ’D 

ACX03590120 

PUMP ASSEMBLY WITH 13’ TUBING AND 31.68 GPD SPARE FEED TUBE

1

CAX-3504 

PVC BLUE SUCTION TUBE(SOFT) (13 FT ROLL)

CAX-3505 PVC 

BLUE 

SUCTION TUBE(SOFT) (300 FT ROLL)

CAX-3508 

3X7 SANTOPRENE FEED TUBE 6.14GPD 

CAX-3509 ROLLER 

ASSEMBLY for 31.68 GPD 

CAX-3511 

NEXT GEN. PP 1/4" INJECTION CHECK VALVE

CAX-3512 

3X7 SANTOPRENE FEED TUBE-31.68GPD (Standard)

1

CAX-3513 

CLEAR FRONT HAYWARD COVER LENS FOR THE PUMP

CAX-3514 SECONDARY 

CATCH 

BASIN 

GLX-LFCAPY 

YELLOW TANK CAP 100mm 

1

GLX-LFTUBE 

PICK UP TUBE ASSEMBLY WITH FITTING, SEAL RING and INLET FILTER

1

GLX-LFCOVER COVER, 

Rain 

Shield 

1

GLX-LFTANK 

15 GALLON TANK WITH PUMP MOUNTING BRACKET

Feed Tube 

CAX-3512 or 

CAX-3508 

 

Pick Up Tube 

Assy 

CLX-LFTUBE 

 

PUMP – AC03590120 

Summary of Contents for AQL-CHEM4-CHLOR

Page 1: ...ING warns about hazards that could cause serious personal injury death or major property damage and if ignored presents a potential hazard CAUTION warns about hazards that will or can cause minor or m...

Page 2: ...h are dam ment hazards on outlet cover a suction outlet a mechanical b ed to a large po re applied direc n cracked mis y swimsuit ha al entrapment ent Hazards by a person a m e i e floor or w int ocat...

Page 3: ...e electrical equipment and have the problem corrected by a qualified service representative before using CAUTION HAYWARD pumps are intended for use with permanently installed pools and may be used wit...

Page 4: ...ause severe le maintaini and seek me enter or phy ncluding chem ast 20 minut cleaned befo s If eye cont clear water f ne can cause at an approv for significan o be used w ollers It s e location o inst...

Page 5: ...he blue tubing and remove the tubing from the feed tube fittings 5 Lift and remove the feed tube fitting on the lower left side inlet of the pump from its seat by sliding it away from the tank Lift an...

Page 6: ...8 3X7 SANTOPRENE FEED TUBE 6 14GPD CAX 3509 ROLLER ASSEMBLY for 31 68 GPD CAX 3511 NEXT GEN PP 1 4 INJECTION CHECK VALVE CAX 3512 3X7 SANTOPRENE FEED TUBE 31 68GPD Standard 1 CAX 3513 CLEAR FRONT HAYW...

Page 7: ...rkmanship for a period of ONE 1 year from the date of purchase when used in single family residential applications The limited warranty excludes damage from freezing negligence improper installation i...

Page 8: ...e Date ____________ ____________ s e individual se or those individ or the overall p f the product p arding Hayward on Street Eliza WWW HAYWAR ompletely and m STEM Register onlin ARD GENUIN T REGISTRA...