08/18
Model 8605WC
Page 2 of 4
LOCATION OF UNIT:
The Model 8605WC Barrier Free Emergency Shower &
Eye/Face Wash Booth should be installed in close proximity to potential accident
areas. It should be clearly identified free from obstructions and easy to access.
SUPPLY LINE:
The minimum recommended line size is 1” IPS with 30-90 psi (2-6
ATM) flowing pressure. Where sediment or mineral content is a problem, an inlet filter
is recommended.
PLUMBING CONNECTIONS:
Inlet supply is female 1” IPS. Waste outlet is 3” IC
(Inside caulk).
TROUBLESHOOTING
PROBLEM REPAIR CHECKLIST
1.
No flow.
1.
Check the main shut-off valve.
2.
Insufficient water flow.
2.
Verify minimum 30 psi (2 ATM)
flowing supply line pressure.
3.
Insufficient water flow. On
eyewash, however, shower is
sufficient.
3. a.
Probable clogging of flow control
due to inadequate line flushing.
Unscrew eye/face wash head and
remove the four screws to
disassemble the head. Clean flow
control and reassemble head. See
SP65 Installation Drawing for details.
4.
Insufficient water flow at the
showerhead, however,
eyewash is sufficient.
4.
Probable clogging of flow control
inside showerhead. Unscrew
showerhead off of elbow and clean
rubber flow control.
5.
Eyewash stream does not meet
desired eye level.
5.
Possible blocked flow control, see
above solution. Possible non-
leveled eyewash assembly.
6.
Water does not drain properly.
6.
Check the main waste line of your
building to see if it does handle the
capacity required for the entire
drainage system.
For more information on Haws products, see our website:
© 2018 Haws
®
Corporation – All Rights Reserved
HAWS
®
and other trademarks used
in these materials are the exclusive property of Haws Corporation.