1. HOLD ROUGH-IN DIMENSIONS ±1/8" (3.2mm).
2. WHEN INSTALLING THIS UNIT, LOCAL, STATE, OR FEDERAL
CODES SHOULD BE ADHERED TO FOR INSTALLATION
DIMENSIONS (LOCATIONS), WASTE AND SUPPLY REQUIREMENTS
OTHER THAN SHOWN.
INSTALLER MUST PROVIDE TRAP FOR PROPER INSTALLATION.
REMOVE VALVE FROM PUSH BUTTON TO INSTALL WASTE
ELBOW ONTO BOWL. AFTER WASTE ELBOW IS INSTALLED,
REINSTALL VALVE AND ADJUST FLOW.
REFER TO 5874 SERIES OPERATION AND MAINTENANCE MANUAL
FOR PUSH BUTTON AND VALVE INSTALLATION/MAINTENANCE
INSTRUCTIONS.
REFER TO RKHO SERIES OPERATION AND MAINTENANCE
INSTRUCTIONS FOR TRANSFORMER AND SENSOR SETUP.
3 [76]
28 3/4 [730]
SUPPLY
33 3/4 [857]
SUPPLY
[867mm]
34-5/32"
(TO SPOUT
OUTLET)
[994mm]
39-5/32"
(TO SPOUT
OUTLET)
27 [686]
32 7/8 [835]
WASTE
27 7/8 [708]
WASTE
6700.4 MOUNTING PLATE
(BEHIND FINISH WALL)
Ø3/8" SUPPLY TUBING
AND SCREWDIRVER STOP
(NOT SUPPLIED)
A
16 [406]
16 [406]
14 1/8 [359]
WASTE BEND AND 1-1/4" IPS TRAP
(NOT SUPPLIED)
16 [406]
32 [813]
16 3/4 [425]
25 1/2 [648]
BACK PANEL
(SUPPLIED)
OPTIONAL TRAP ACCESS PANEL
MODELS 6603 AND 6603HPS
DETAIL A
1-1/4" O.D.
WASTE BEND
(SUPPLIED)
MOUNTING BOLTS
(NOT SUPPLIED)
16 [406]
16 [406]
36 [914]
10 [254] 12 [305]
2 1/8 [55]
7 1/8 [182]
1 7/8 [47]
2 [51]
3 [76]
6700.4 MOUNTING PLATE
MUST BE INSTALLED BEFORE FINISH WORK.
THIS PLATE IS REQUIRED - SOLD SEPARATELY.
NOTES:
3
4
3
4
FLOOR LINE
WALL FACE
WALL STUD
WALL FACE
8X 3/8-16 UNC
4X ø7/16" [ø11]
5
18 5/8 [473]
APPROVED:
DRAWN:
PART NUMBER
SCALE:
SHEET
OF
REVISION
DRAWING TYPE:
SIZE: A
BY:
ECN NO.
PA
GE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
FV
09/15/20
1
0510001066.D
1011HO/1011HO2/1011HPSHO/1011HPSHO2
1:1
1
2
FV
10/01/20
5579
SLS
6 of
7
INSTALLATION
5579
2020
FV
5
SOLENOID
NEUT
BLK
RED
SENSOR
TO VALVE
24VAC IN
24VAC
SW 24VAC
J2 1
2
TRANSFORMER
WHT
CABLE WIRING DIAGRAM
NOT USED
TRANSFORMER STYLE
SHOWN MAY NOT
REFLECT ACTUAL
TRANSFORMER USED
120VAC-24VAC
TRANSFORMER
AND HO CABLE
(SUPPLIED)
FROM DIRECT
CONTACT WITH WATER
MUST BE PROTECTED
6
6
LOCATE AND INSTALL
ELECTRICAL
24VAC SOLENOID VALVE
TRANSFORMER
WITHIN WALL
SENSOR
EYE
6
6
REGULATOR
MODEL 1011HO/1011HPSHO SHOWN
MODEL 1011HO2/1011HPSHO2 ON SHEET 2
(ROUGH-IN DIMENSIONS APPLY TO ALL 4 MODELS)