RECOMMENDED TOOLS

: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable 

wrench, 

10" pipe wrench, 3/32” and 5/32 “ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or 

open-end wrench.

 

LOCATION OF UNIT:

 The Model 1011HO/1011HO2/1011HPSHO/1011HPSHO2 Drinking 

Fountain is a wheelchair accessible drinking facility. The height dimensions shown, meet 
current ADA requirements. When installing this unit, local, state or federal codes should be 
adhered to. If height other than shown is required, then dimensions must be adjusted 
accordingly. 

SUPPLY LINE

: T

he minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM) 

flowing pressure. Where sediment or mineral content is a problem, an inlet filter is 
recommended. 

PLUMBING CONNECTIONS:

 

Inlet is 3/8” O.D. tube push-in type fitting. Waste outlet is 1-1/4” 

O.D. tube. 

ELECTRICAL CONNECTIONS

Drinking Fountain may be mounted on external wall of 

building provided transformer shall be mounted inside the wall and protected from 
water as shown on RKHO Series O&M details (page 8) per NEC/CEC and local code.

 

  Sensor(s)

      

1011HO/1011PSHO with RKHO.120/120P

:

 120 x 24 VAC, 60Hz, .68 AMPS. 

      1011HO/1011HPSHO with RKHO.240

:

 240 x 24 VAC, 60Hz, .68 AMPS. 

      1011HO2/1011HPSHO2 with RKHO.120/120P

:

 120 x 24 VAC, 60Hz, 1.36 AMPS. 

      1011HO2/1011HPSHO2 with RKHO.240

:

 240 x 24 VAC, 60Hz, 1.36 AMPS. 

MAINTENANCE: 

Periodically clean the strainer (Located inside push button valve on Models 

1011HO/1011HPSHO). Refer to 5874 Series Valve Manual for more information. 

 

INSTALLATION PROCEDURE 

 

GENERAL NOTES: 

 

1.  For all plastic push-in type fitting connections, only connect NSF-61 copper or 

plastic tubing. Stainless steel or glass tubing is not recommended. The 
following assembly instructions must be followed to ensure a watertight 
connection: 

a.  Cut tubing square and clean. 
b.  Mark from end of tube the length of insertion (See table below). 
c.  Push tube into the fitting until it bottoms out. 
d.  To remove, depress collet and pull tubing out. 

 

Tube Sizes 

O.D. 

Tolerance 

Insertion Depth 

1/4” 

±.005” 

11/16” 

3/8” 

±.00

5” 

3/4” 

1/2” 

±.005” 

7/8” 

 

 

CLEANING INSTRUCTIONS FOR HI-POLISHED STAINLESS PRODUCTS: 

Haws

’ recommended cleaning procedure for hi-polished stainless products is as follows: 

 

Use a mild detergent or soap and water for removing stains and fingerprints or use a clean cloth 
with window cleaner. 

Summary of Contents for 1011HO

Page 1: ...inspection HAWS will not be liable for the cost of repairs alterations or replacements or for any expense connected therewith made by the owner or his agents except upon written authority from HAWS S...

Page 2: ...s page 8 per NEC CEC and local code Sensor s 1011HO 1011PSHO with RKHO 120 120P 120 x 24 VAC 60Hz 68 AMPS 1011HO 1011HPSHO with RKHO 240 240 x 24 VAC 60Hz 68 AMPS 1011HO2 1011HPSHO2 with RKHO 120 120P...

Page 3: ...height using the black pressure regulator mounted inside bracket that has HO sensor unit by loosening the locknut and rotating the knob clockwise to increase flow or counterclockwise to reduce flow T...

Page 4: ...NGED W VALVE 2 VRK5874 3 PBA6 4 0004012000 5 6700 4 6 6463 7 6603 8 PBM1000 9 10 0002082253 5705 VALVE REPAIR KIT BUTTON PUSH 5874 FLANGED PANEL BACK F SATIN SWIRL OR HI POL SS PLATE MOUNTING STRAINER...

Page 5: ...359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SU...

Page 6: ...6700 4 MOUNTING PLATE MUST BE INSTALLED BEFORE FINISH WORK THIS PLATE IS REQUIRED SOLD SEPARATELY NOTES 3 4 3 4 FLOOR LINE WALL FACE WALL STUD WALL FACE 8X 3 8 16 UNC 4X 7 16 11 5 18 5 8 473 APPROVED...

Page 7: ...ASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE FV 09 15 20 1 0510001066 D 1011HO 1011HO2 1011HPSHO 1011HPSHO2 1 1 2 2 FV 10 01 20 5579 SLS 7 of 7 INSTALLATION 5579 2020 FV MODEL 1011HO2 1011HPSHO2 SHOWN...

Reviews: