09/20
MODEL 1011HO/1011HO2/1011HPSHO2/1011HPSHO2
PAGE 2 OF 7
RECOMMENDED TOOLS
: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable
wrench,
10" pipe wrench, 3/32” and 5/32 “ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or
open-end wrench.
LOCATION OF UNIT:
The Model 1011HO/1011HO2/1011HPSHO/1011HPSHO2 Drinking
Fountain is a wheelchair accessible drinking facility. The height dimensions shown, meet
current ADA requirements. When installing this unit, local, state or federal codes should be
adhered to. If height other than shown is required, then dimensions must be adjusted
accordingly.
SUPPLY LINE
: T
he minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM)
flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.
PLUMBING CONNECTIONS:
Inlet is 3/8” O.D. tube push-in type fitting. Waste outlet is 1-1/4”
O.D. tube.
ELECTRICAL CONNECTIONS
:
Drinking Fountain may be mounted on external wall of
building provided transformer shall be mounted inside the wall and protected from
water as shown on RKHO Series O&M details (page 8) per NEC/CEC and local code.
Sensor(s)
:
1011HO/1011PSHO with RKHO.120/120P
:
120 x 24 VAC, 60Hz, .68 AMPS.
1011HO/1011HPSHO with RKHO.240
:
240 x 24 VAC, 60Hz, .68 AMPS.
1011HO2/1011HPSHO2 with RKHO.120/120P
:
120 x 24 VAC, 60Hz, 1.36 AMPS.
1011HO2/1011HPSHO2 with RKHO.240
:
240 x 24 VAC, 60Hz, 1.36 AMPS.
MAINTENANCE:
Periodically clean the strainer (Located inside push button valve on Models
1011HO/1011HPSHO). Refer to 5874 Series Valve Manual for more information.
INSTALLATION PROCEDURE
GENERAL NOTES:
1. For all plastic push-in type fitting connections, only connect NSF-61 copper or
plastic tubing. Stainless steel or glass tubing is not recommended. The
following assembly instructions must be followed to ensure a watertight
connection:
a. Cut tubing square and clean.
b. Mark from end of tube the length of insertion (See table below).
c. Push tube into the fitting until it bottoms out.
d. To remove, depress collet and pull tubing out.
Tube Sizes
O.D.
Tolerance
Insertion Depth
1/4”
±.005”
11/16”
3/8”
±.00
5”
3/4”
1/2”
±.005”
7/8”
CLEANING INSTRUCTIONS FOR HI-POLISHED STAINLESS PRODUCTS:
Haws
’ recommended cleaning procedure for hi-polished stainless products is as follows:
Use a mild detergent or soap and water for removing stains and fingerprints or use a clean cloth
with window cleaner.