3.7 Critical process parameters
3.7.1 Sealing temperature
The temperature is monitored electronically by means of a temperature sensor.
If this varies from the set value by 5°C (requirements set out in DIN 58953-7:2010),
the error message is displayed (see section 4.3.2 Error displays)
3.7.2 Contact pressure
The contact pressure is monitored electronically by means of a force sensor.
If this varies from the factory-set value,
the error message is displayed (see section 4.3.2 Error displays)
3.7.3 Sealing time
To guarantee a reproducible sealing seam, the sealing time is also relevant as a further
process parameter.
The sealing time ex-works is 10m/min.
If this varies from the set value by 10%,
the error message is displayed.(see section 4.3.2 Error displays)