background image

Summary of Contents for hd 650 D EcoPak

Page 1: ...9 693 004 OPERATING INSTRUCTIONS Valid for device versions hd 650 D DE EcoPak hd 650 D DE EcoPak...

Page 2: ...ANCE 13 4 1 TROUBLESHOOTING CHECKLIST 13 4 2 OFFSET SETTING THE TEMPERATURE 14 4 2 1 Revoke key lock 14 4 2 2 Offset Make setting 14 4 2 3 Activate key lock 14 4 3 HAWO CUSTOMER SERVICE 15 4 4 SERVICI...

Page 3: ...sealable transparent pouches and reels med packaging 1 2 Legend The exclamation mark in the triangle draws your attention to important notes in the operating instructions which must absolutely be obse...

Page 4: ...with standards not listed in the declaration of conformity In the event of conversion work or interventions to the device undertaken without the express written permission of the manufacturer the warr...

Page 5: ...rs 7 The device must be connected using the mains cable included in the scope of delivery to a protective contact socket with a stable voltage Operation on IT networks is not permitted 8 Place the dev...

Page 6: ...g parts Loose clothing jewellery or long hair can be caught by moving parts 21 The device contains valuable materials that can be recycled and reused The device should therefore be disposed of at a pu...

Page 7: ...lable pouches and tubes in accordance with ISO EN 11607 1 EN 868 5 made of film and uncoated materials made of polyolefins as per EN 868 9 e g Tyvek 1 x2 Sealable pouches and tubes in accordance with...

Page 8: ...ing is now transported and the area is heated to the set sealing temperature Step 3 The sealing seam which is now heated is pressed together by the sealing rollers and sealed Step 4 The finished steri...

Page 9: ...and where the mains voltage is stable The device may only be installed in a dry environment Heavy dust steam dripping water or splashing water impair the function of the device Please make sure that t...

Page 10: ...n Switch on the device with the mains switch in position 1 The indicator light in the switch is lit Set the required sealing temperature on the temperature controller as described in Chapter 3 3 The d...

Page 11: ...on the outlet side and allow to cool down briefly Check of the sealing seam If leaks appear the sealing temperature must be increased If the film melts the set temperature is too high As per DIN 58953...

Page 12: ...l Menu Confirm LED 1 Process status display LED 4 Heating status Input of the set temperature The key is pressed once Confirm MENU User Level selection level by pressing the key twice Setting the temp...

Page 13: ...l trips it is imperative to have the device tested Temperature controller Replace temperature controller Heating cartridge Check heating cartridges and replace if necessary Solid state relay Replace s...

Page 14: ...keys 3 Press the Menu OK key 4 CONFIGURATION level Switch to ANALOG INPUT with the arrow keys 5 Press the Menu OK key 6 ANALOG INPUT level Switch to MEASURING VALUE OFFSET with the arrow keys 7 Press...

Page 15: ...a trained professional at least once a year Maintenance cycle Cleaning PTFE tape Guiding die PTFE tape Sealing die Pressure roller Toothed belt Distance of Sealing die At least every 3 months Dependi...

Page 16: ...V Time controller 230 V 1 540 056 1 540 057 115 V Heating cartridge 115 V 200W 6 536 032 Fan 230 V 6 212 019 6 212 021 115 V PTFE tape heating die 6 105 125 PTFE tape guiding die 6 105 138 IEC cable...

Page 17: ...s ordering allocation of article numbers 4 6 1 Upper sealing die 1 616 024 4 6 2 Lower sealing die 1 616 025 6 536 032 Heating cartridge 6 564 040 Temperature sensor 6 105 125 PTFE tape 6 536 032 Heat...

Page 18: ...hd 650 D DE EcoPak D Chapter 4 9 693 004 Page 18 V 5 01 4 6 3 Upper guiding die 1 619 014 4 6 4 Lower guiding die 1 619 015 6 105 138 PTFE tape 6 105 138 PTFE tape...

Page 19: ...5 Comprehensive overview 6 271 001 Toothed belt transport 1 561 016 Opto Sensor motor start hd 650 DE only 6 562 009 IEC Cable supply 1 212 005 or 1 212 014 Gear motor 6 564 050 Controller 2 230 026...

Page 20: ...ontroller 6 564 050 Temperature sensor 6 564 040 Overtemperature protection 6 564 018 SST relay 6 460 001 115V 200W heating cartridges 6 536 024 Gear motor 230V 1 212 005 115V 1 212 014 Optical sensor...

Page 21: ...hd 650 D DE EcoPak D Chapter 5 9 693 004 Page 21 V 5 01 5 2 Switching and wiring diagram 115V...

Page 22: ...mm 12 Sealing system Multi Line Length of sealing seam mm Unlimited Distance from medical product mm 30 as per DIN 58953 7 Process variables sealing parameters Sealing temperature max C 220 Sealing t...

Page 23: ...hd 650 D DE EcoPak D Chapter 6 9 693 004 Page 23 V 5 01 6 Declaration of conformity...

Page 24: ...o com www hawo com hawo USA 321 North Clark Street Suite 1425 Chicago IL 60654 T 1 312 585 8329 F 1 312 644 0738 info hawo usa com www hawo usa com hawo ASIA 25 International Business Park 03 105 Germ...

Page 25: ......

Reviews: