background image

Commissioning - Software

MiniWave

 

User Manual

7

Startup

The MiniWave uses automatic sensitivity control to detect and maintain the level. After applying power to the 
unit allow 20-30 seconds for the unit to adjust to the application*.

Parameter

Description

 

Options

Display Mode Set LCD measurement display mode

Level

% Level

Space

Volume*

Display Unit

Adjust displayed measurement unit

MilMetre

CenMetre Metres

Feet

Inches

Low Level

Set Low level measurement point (4mA)

Adjustable

High Level

Set High level measurement point (20mA) Adjustable

Damping

Adjust output response time & smoothness

Adjustable in seconds

Failsafe

Set failsafe output

3.50mA
4mA

3.80mA
20mA

20.20mA
LastKnown

Setup

Main Menu

Setup

Advanced

Autoset

Setup

Display Mode

Display Unit

Low Level

Hi Level

Damping

FailSafe

Advanced

Comms

Echo Size

Lock Code

Analogue

Language

Autoset

See (B) Autoset

Main Menu

Setup

Advanced

Autoset

Setup

Display Mode

Display Unit

Low Level

Hi Level

Damping

FailSafe

Advanced

Comms

Echo Size

Lock Code

Analogue

Language

Autoset

See (B) Autoset

AutoSet

Use AutoSet to scan and program the unit High or Low level to the distance detected. After the scan you will 
be prompted to accept the distance measured. The High and Low level can also be manually adjusted in 
'Setup'.

 185 mm (7.3”)

 

52mm 

(2”)

 72mm  (2.8”)

 47mm (1.85”)

2" BSP or 

NPT THD

 85mm (3.4”) 

M20

Cable 

Gland

M20 Blank Plug

+

-

23mm (0.9”)

+

-

CAL

RUN

Space

1.402m

17.2mA

m i n i   w a v e

Space

1.402m

17.2mA

Set Lo Level

Set Hi Level

AutoSet

SCANNING

Set Lo Level

No

Yes

       2.597m 

Set Lo Level

 185 mm (7.3”)

 

52mm 

(2”)

 72mm  (2.8”)

 47mm (1.85”)

2" BSP or 

NPT THD

 85mm (3.4”) 

M20

Cable 

Gland

M20 Blank Plug

+

-

23mm (0.9”)

Flip Lid

to access

terminals

+

-

CAL

RUN

Space

1.402m

17.2mA

m i n i   w a v e

Space

1.402m

17.2mA

Set Lo Level

Set Hi Level

AutoSet

SCANNING

Set Lo Level

No

Yes

       2.597m 

Set Lo Level

Main Menu

To access the Main menu press

To access AutoSet menu press and hold              for 3 seconds

*For best results ensure there is a 
liquid level present in the application 
or flat surface below the transducer

* Volume mode requires PC with GoshawkII software. Consult dedicated MiniWave GoshawkII Manual 

Summary of Contents for MiniWave Ultrasonic Level Series

Page 1: ...MiniWave Ultrasonic Level Series Liquid Level Measurement User Manual Sultan Sonar Manual Rev 1 0 A Higher Level of Performance www hawkmeasure com For more information please visit...

Page 2: ...Commissioning Software 7 Startup 7 Main Menu 7 Setup 7 AutoSet 7 Advanced Settings 8 HART 9 HART Universal Common Practice command list 9 Troubleshooting 10 Unit is displaying incorrect distance 10 An...

Page 3: ...ndustries Principle of Operation The MiniWave emits an ultrasonic pulse which is reflected from the surface of the liquid being measured The reflected signal is processed using specially developed sof...

Page 4: ...ring 15mm 0 60 2 NPT or BSPT INTERNAL THREAD 152mm 6 0 4 x 19mm 0 75 HOLES THROUGH 120mm 4 7 P C D FA2NB 4 2 ANSI Polypropylene Flange for NPT threaded units FA2BB 4 2 ANSI Polypropylene Flange for BS...

Page 5: ...re of a curved roof to avoid the potential of parabolic echoes Ensure appropriate UV protection 2 NPT MWN1A or 2 BSPT MWB1A min 250mm 10 min 250mm 10 These are examples of common INCORRECT mountings w...

Page 6: ...e Space 1 402m 17 2mA SCANNING Set Lo Level No Yes 2 597m Set Lo Level Diagnostic Display Mode Interface Button Action Navigation Function Press and release Press and hold for 3 seconds Access Main M...

Page 7: ...toset See B Autoset Main Menu Setup Advanced Autoset Setup Display Mode Display Unit Low Level Hi Level Damping FailSafe Advanced Comms Echo Size Lock Code Analogue Language Autoset See B Aut AutoSet...

Page 8: ...EchoSize The unit will target this echo size measured in signal voltage during operation High values can increase stability but make the unit more susceptible to false echoes Lower values can make th...

Page 9: ...ident associated with tag 12 Read message 13 Read Tag Description Date 14 Read PV sensor information 15 Read output information 16 Read final assembly number 17 Write message 18 Write Tag Description...

Page 10: ...ng with the transit pulse in the application such as ladders and cross beams Unit is locked up or flat line measurement Confirm there is material within measurement range the unit may go to Failsafe i...

Page 11: ...cessories FA2NB 4 2 ANSI Polypropylene Flange for NPT threaded units FA2BB 4 2 ANSI Polypropylene Flange for BSPT threaded units Hawklink MiniUSB PC connecter for GoshawkII Model Type MWN1A MiniWave w...

Page 12: ...t Resolution 1 mm 0 04 Electronic Accuracy 0 25 of maximum range Operating Temperature 40 C to 60 C 40 F to 140 F Maximum Operating Pressure 0 5 to 3 bar 0 44 PSI Automatic Temperature Compensation Ye...

Page 13: ...Contact MiniWave User Manual 13 13 13...

Page 14: ...Overview MiniWave User Manual 14 14...

Page 15: ...Overview MiniWave User Manual 15 15...

Page 16: ...he need for immediate technical assistance The HawkLink 3G communication device allows any computer with internet access and our free GosHawk diagnostic calibration software to dial in calibrate test...

Reviews: