MAINTENANCE
7
1. Do not carry out any maintenance whilst compressor is on - ensure
motor is not running, compressed air and condensation is bled and
compressor is disconnected from any power supply (see pages 5 + 6).
2. Clean crank case and renew lubricating oil after the first 10 working
hours.
3. Check the oil levels after every use and replenish if necessary.
4. To replenish oil, remove bolt from sump, drain off any old oil and
replace with new. Never mix old and new oil.
5. Clean air filter every 3 months.
6. Have the safety valve and pressure gauge checked by a certified repair
centre every 6 months to ensure they are in the correct working
condition.
7. Make sure the air tank is not damaged and no rust has formed.
8. Have the thickness of the air tank checked by a certified repair centre
every year to ensure the tank thickness is not less than 2.1mm.