www.hawe.de | 2015
09-2015-1.0 - D 7818/1 - EV2S-CAN
7
3.2 Electrical parameters
Supply voltage
U
B
8 to 32 V DC, pole-protected
Output voltage
U
A
U
B
– 0.5 V, pulse-width modulated
Unregulated output current
I
A
max. 0 to 2 A, short-circuit proof, temperature-dependent
Regulated output current
I
A
max. 0 to 1.6 A, short-circuit proof, temperature-dependent (see diagram 1)
Adjustment areas
I
min
0 to 1 A
I
max
0 to 2A
Idle current
I
L
<35 mA
Possible input signal 1
•
0 to 5 V DC, R
E
= 36 k
U
•
0 to 10V DC, R
E
= 36 k
U
•
4 to 20 mA, R
E
= 220 k
U
•
0.25 U
B
… 0.75 U
B
, R
E
= 24 k
U
•
PWM, R
E
= 36 k
U
Possible input signal 2
•
0 to 5 V DC, R
E
= 24 k
U
•
0 to 10V DC, R
E
= 24 k
U
•
CAN
•
*
10 V DC, R
E
= 24 k
U
Recommended target value potentiometer
R
Ò
10 k
U
Ramp time
t
R
0 to 300 s
Increase and decrease time can be adjusted separately
Dither frequency
f
50 to 1,000 Hz
Dither amplitude
l
0 to 50%
PWM frequency
f
50 to 1,000 Hz (temperature-dependent)