The service button can be used to wake the LED display, and either put the system into or out of service
mode, as well as cycle through various operating modes.
IMPORTANT! In the event that the system has gone out of service, please consult your installer for
guidance. Depending on the nature of the service fault, out technical department may advise you to
reset the system on your own, or schedule a service visit.
Backup Power Operation
This system will provide limited backup power to dedicated
electrical outlets located inside the protected loads electrical
sub panel.
The Powerblocks battery energy storage
system will not supply power to the entire home during a
grid outage.
There is an option to hard wire limited
emergency circuits from within the home to this protected
load panel for an additional fee. The power source is limited in
power rating and duration, both of which are dependent on
the nature of the loads connected to the system, and the
available solar supply. This system is designed to reliably
provide power to a refrigerator, home lighting, home
electronics, and small appliances. Please refer to the document
titled [Powerblocks - Understanding Protected Loads] for more information.
NOTE:
While the battery system does provide grid quality backup power (pure sine wave) following a
grid outage, the power in the home will be interrupted for up to four seconds before backup power
generation commences. As a result of this interruption, a desktop or portable Uninterruptible Power
Supply (UPS) is recommended if continuous operation is desired for any electronic devices.
I
MPORTANT!
Surge rated loads (compressor and motor type loads) may greatly reduce the power
output capability of the battery system, and cause premature overload conditions. Equipment of this
type that is connected to the backup panel should be inspected and tested regularly as per
manufacturer suggested schedules. Do not attempt to add loads of this type to the backup panel
without consulting your installer. Permanent damage to the battery system and/or your equipment may
occur if exposed to chronic overloading cycles.
IMPORTANT!
Portable extension cords connected to a backup circuit should be limited to 30 feet.
hawaiienergyconnection.com
May 2020