background image

1)   the   appliance   is   put   into   standby   mode   by   pressing   standby   

  button.   

 

2)   the   appliance   suffers   power   disconnection.   

 

You   need   to   set   again   by   pressing   M   for   3   seconds   if   you   need   this   function.   

 

 

 

6.   Window   detector   function 

 

 

Press  

 to  enter  window  detecor  function.  Then  press  “ 

”  to  choose  “ON”  or  “OFF”.  

 

   

 

 

 

 

 

 

   

 

   

 

If   “ON”   is   selected,   the   window   detection   function   is   activated   and   

 icon   will   show   on   the  

 

   

 

 

 

 

   

 

 

 

 

 

 

 

 

screen.  When  temperature  decrease  detected,  the  appliance  will  automatically  enter  anti-freeze  

 

 

 

 

 

 

 

 

 

 

 

mode   with   

 icon   flashing.   If   temperature   rises   up,   the   appliance   will   go   back   to   previous  

 

 

 

 

   

 

 

 

 

 

 

 

   

 

mode   with   

  icon   on.   You   can   choose   “OFF”   to   inactivate   the   window   detection   function.    

  

Remarks:   the   window   detector   function   is   not   available   under   anti-freeze   mode.    

  

 

 

7.   In   case   of   power   failure 

 

 

If   the   power   supply   is   cut,   after   recovery,   the   unit  goes  into  standby  mode.  You  can  press  the  

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

  button   to   return   to   the   selected   mode   and   temperature   before   the   power   failure.   

 

The  device  keeps  in  memory  only  the  parameters:  temperature  and  operating  mode.  When  the  

 

 

   

 

 

 

 

 

 

 

 

 

 

power   is   turned   back   on,   When   power   is   restored,   the  clock  must  be  set  again  to  operate  the  

   

 

 

 

 

   

 

 

 

 

 

 

   

 

 

various   programs   correctly.   

 

 

 

   

 

 

TECHNICAL   SPECIFICATIONS  

 

 

 

 

 

   

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Information   requirements   for   electric   local   space   heaters 

 

 

 

 

12   

 

 

 

Model 

 

 

Voltage 

 &  

 

 

Frequence 

 

 

Rated   

Power 

 

 

Product   dimension 

 

 

L   X   W   X   H  

 

 

 

(in   mm) 

 

 

Class 

 

 

Protection   

Index 

 

 

HT10PD 

 

 

230V-   50Hz   

 

1000W   

 

564*110*450   

 

CLASS   II   

 

IPX4   

 

HT15PD 

 

 

230V-   50Hz   

 

1500W   

 

714x110*450  

CLASS   II   

 

IPX4   

 

HT20PD 

 

 

230V-   50Hz   

 

2000W   

 

864x110x450   

 

CLASS   II   

 

IPX4   

 

Model   identifier(s):   HT10PD 

 

 

Item 

 

 

Symbol 

 

 

Value 

 

 

Unit 

 

 

   

Item 

 

 

Unit 

 

 

Heat   output 

   

  

   

Type  of  heat  input,  for  electric  storage  local  space 

   

 

 

 

 

 

 

 

heaters   only   (select   one) 

   

  

Nominal   heat   output   

 

nom 

 

 

 

 

x,x   

 

kW   

 

    manual   heat   charge   control,   with 

 

 

 

 

 

NA  

 

 

 

Summary of Contents for 8423055007336

Page 1: ...sed several tests and control in order to ensure its quality It is conceived to bring you an optimal comfort without any maintenance Thank you for choosing us and your trust 1 SAFETY INSTRUCTIONS Mean...

Page 2: ...The device must not be used outdoors The device should not be removed to avoid the risk of electric shock The device is only intended for domestic use Do not apply pressure to the front of the unit or...

Page 3: ...provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understan...

Page 4: ...e instructions for the heater intended to be fixed by screws on the method of fixing thanks to refer to the section INSTALLATION of the manual WARNING In order to avoid a hazard for very young childre...

Page 5: ...and the weight of the device INSTALLATION IN THE BATHROOM Warning this product shall be used in the volume 2 only according to the national wiring rules For France NF C 15 100 Note The drawing is for...

Page 6: ...sidual current device RCD having a rated residual operating current not exceeding 30 mA The appliance must not be connected to the earth wire yellow and green wire ELECTRICAL CONNECTION Blue or light...

Page 7: ...osening the screw do not remove only loosen and slide the metal plate out of the hole Take out the bracket by pulling down Figure 2 3 Verify that the bracket is horizontal with a spirit level and mark...

Page 8: ...cket Figure 5 LCD display 8 Symbol Function Mode standby the appliance doesn t work but with power on Mode anti freeze the appliance maintains the temperature around 7 C Mode comfort set the desired t...

Page 9: ...e If the device is in operation changing the time setting Press both and buttons at the same time and enter the time setting Press to toggle between hours minutes day of the week 1 7 Press the button...

Page 10: ...eriods 00 00 24 00 Select the desired day 1 7 by pressing buttons Press the PRG button to set the heating mode of different period 00 00 24 00 Press button to choose hours and to choose among function...

Page 11: ...e difference between the ECO mode and the COMFORT mode is 3 5 C Each time you press the buttons to adjust the temperature you increase or decrease the temperature by 0 5 C Press any other button excep...

Page 12: ...er failure If the power supply is cut after recovery the unit goes into standby mode You can press the button to return to the selected mode and temperature before the power failure The device keeps i...

Page 13: ...mechanic thermostat room temperature control no with electronic room temperature control no electronic room temperature control plus day timer no electronic room temperature control plus week timer ye...

Page 14: ...ic room temperature control plus day timer no electronic room temperature control plus week timer yes Other control options multiple selections possible room temperature control with presence detectio...

Page 15: ...standby mode elSB 0 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic room tempera...

Page 16: ...quids abrasive detergents or chemicals alcohol petrol etc for cleaning IMPORTANT The symbol opposite indicates the device may contain detrimental materials in small quantities to the environment There...

Reviews: