8    Maintenance 

 

 

14

8

 

Maintenance 

Replacing the block battery 

 
 

 
 
 
 
 

 
 
 
 

 
 

NOTE: 

Do not dispose of batteries with the 
household garbage (see page 18: ”Disposal 

of batteries”).

 

 

Cleaning the SCD 

 
 
 
 
 

 
 
 
 
 

1.

 

Open the battery compartment lid at 
the rear of the SCD. 

2.

 

Remove the block battery from the 
compartment and separate from the 
connection clip. 

3.

 

Connect a new block battery to the 
connection clip, and insert battery 

into compartment. 

4.

 

Reattach the lid to close the battery 
compartment. 

1.

 

Moisten a dust- and lint-free cloth with 
our special cleaning agent SRM1 or 
with medical-grade alcohol. 

2.

 

Clean the spacer pins and sensor 
plate using the moistened cloth. 

3.

 

Allow the SCD to dry before 
performing a measurement. 

Fig. 2 

Fig. 3

NOTE: 

Reliable measuring values will not be 
provided unless the cleaning agent has 
evaporated completely.

 

 

Summary of Contents for Static Control Digital

Page 1: ...gen Phone 49 711 94 98 0 Telefax 49 711 94 98 298 www haug de E Mail info haug de HAUG Biel AG Johann Renfer Strasse 60 CH 2500 Biel Bienne 6 Phone 41 32 344 96 96 Telefax 41 32 344 96 97 www haug ion...

Page 2: ...Fig 3 Fig 2 Fig 1...

Page 3: ...roduction 4 2 Scope of delivery 5 3 Operator instructions 6 4 General safety instructions 8 5 Intended use 9 6 Description of unit 10 7 Measuring 11 8 Maintenance 14 9 Spare parts 15 10 Technical data...

Page 4: ...here highly insulating materials are used The Static Control Digital enables you to measure such electrostatic charges Where electrostatic charges are present targeted counter measures for their elimi...

Page 5: ...for the first time make sure to check whether your delivery is complete The following parts are included in the delivery Carrying case Static Control Digital 9 V monobloc battery installed Grounding c...

Page 6: ...eviated SCD in these operating instructions General notes regarding your Static Control Digital The SCD has been designed and tested in accordance with the safety regulations for measuring and control...

Page 7: ...perator instructions 7 Symbols used If this safety information is not observed severe injuries or death may result NOTE Important notes and additional information Do not dispose of with household garb...

Page 8: ...ed electrical defects Contact HAUG GmbH Co KG in this case see cover sheet The SCD housing is not protected against moisture Moisture and wetness may therefore enter the SCD This may result in defects...

Page 9: ...sparks may form These may ignite gases dust or similar substances Do not use the SCD in areas with potentially explosive atmospheres The SCD is a measuring unit intended to measure electrostatic charg...

Page 10: ...cription of unit You will find images Figs of the SCD on the inside cover page Front view A Spacer pin B Display C Start button D Ground button Fig 1 Rear view E Battery compartment lid Fig 2 Narrow s...

Page 11: ...or is displayed continuously the voltage is too low for accurate measurement No reliable measuring value can be provided Replace the block battery see page 14 Replacing the block battery NOTE The SCD...

Page 12: ...o the ground socket of the SCD Fig 6 Connect the other end of the grounding cable to a protective ground e g by using the pick off clip Fig 7 NOTE The SCD is calibrated when connected to ground A reli...

Page 13: ...of 000 on the display Fig 8 3 Now approach the surface to be measured with the SCD until the spacer pins come to rest vertically Fig 9 4 Release the Start button The measuring value will now be saved...

Page 14: ...connection clip 3 Connect a new block battery to the connection clip and insert battery into compartment 4 Reattach the lid to close the battery compartment 1 Moisten a dust and lint free cloth with o...

Page 15: ...Spare parts Article Ident number Carrying case X 4568 Spacer pin X 8308 Grounding cable X 6350 Pick off clip X 6349 9 V monobloc battery X 0071 Special cleaning fluid SRM1 10 7220 000 Operating instr...

Page 16: ...tions The meter must not be used in areas with potentially explosive atmospheres or power plants Only for use in interiors Temperature Rated application range 10 C to 35 C Extreme range for storage an...

Page 17: ...re the SCD in its carrying case in a dry and cool location Disposing of the SCD Do not dispose of electrical units with your household garbage Electrical appliances must be collected separately and re...

Page 18: ...osal of batteries Do not dispose of batteries with your household garbage You are obliged to dispose of batteries properly Batteries can be taken to the recycling points in your community or returned...

Page 19: ......

Page 20: ...SCD v02gb doc made by D 0327 GB V02 2011 06 10...

Reviews: