Operating instructions angular electrode and U-shaped electrode
Winkel- und U-Elektroden v02gb
Page 4
2
Safety
The ionizing units of these series are operationally safe, provided that they are operated in
accordance with their intended use.
In case of misuse, dangers may result:
- for life and limb of the operator,
- for the unit and other assets.
Also note Chapter 3.1 (Important installation notes).
For operators with heart pacemakers special instructions should be
requested from the manufacturer!
During operation of the units, small quantities of ozone will form.
In order to ensure adherence to maximum permitted ozone concentrations at the workplace,
make sure that the workplace is ventilated sufficiently during operation of the units.
The operator of the units must take care to ensure sufficient ventilation
during operation!
2.1
Intended use
Ionizing units generate positive and negative ions. Their purpose is the elimination of electrostatic
charges (e.g. in paper, films and foils, textiles, glass, plastics etc.).
HAUG power packs only must be used for supplying the high voltage to the units.
Do not install or use the units in areas
subject to explosion hazards.
For reasons of safety, unauthorized conversions and modifications of the unit are not permitted.
The installation and operating conditions indicated in these Operating Instructions must be
adhered to.
2.2
Danger sources
Defective high-voltage plugs and cables may lead to danger of electric shocks. Shut down the
unit immediately in case of visible damage and suspected electrical defects.
Danger!
High voltage!
Danger of fatal accidents!
Switch off the power pack before connecting
or disconnecting the coaxial connectors!