![Haug Multistat Ex SDN Operating Instructions Manual Download Page 7](http://html1.mh-extra.com/html/haug/multistat-ex-sdn/multistat-ex-sdn_operating-instructions-manual_2107707007.webp)
2 Safety
7
2.1
Intended use
Risk of explosion!
The discharging power pack may generate sparks which ignite
gases, dust or similar substances.
• Never install or use the discharging power pack in areas with
potentially explosive atmospheres.
NOTE:
An operating authorization (ATEX) exists for the discharging power
pack. Only the HAUG Ex ionizing units listed in the operating
authorization must be connected. If other units are connected, the
operating authorization will become null and void.
The discharging power pack is intended exclusively for the supply of
alternating high voltage to HAUG ionizing units with X-2000
connector for use in potentially explosive atmospheres. In
combination with an ionizing unit for use in potentially explosive
atmospheres, electrostatic charges are neutralized in a production
process.
Always observe the installation and operating conditions indicated in
these operating instructions.
Warranty only covers products, accessories or spare parts of HAUG
GmbH & Co. KG.
Summary of Contents for Multistat Ex SDN
Page 2: ......
Page 29: ......
Page 30: ...NOTES...
Page 31: ......
Page 32: ...Multistat Ex SDN v02 1gb docx V02 1 17 09 2018 D 0370 GB made by...