8 Technical data
25
8
Technical data
8.1
Characteristics and specification
Reference temperature 23 °C
HV terminals
4
High-voltage
6,7 ±1 kV~
Short-circuit current
I
k
< 5 mA
Maximum connected length
18 m (ionizing bar + HV cable)
Reset pulse
> 0,5 s
Cannot be used in pulsed mode
Relay contact rating K1/K6
signalling socket
max. 24 V~/35 V=; max. 50 mA
Switching threshold for HV
< 4,2 kV
Switching threshold for mains
failure
< 50 V
8.2
Supply voltage
Unit type
Nominal value
Frequency
range
Power input
01.7960.000
230 V~
±
10 %
50 – 60 Hz
P
max
= 80 VA
01.7961.000
115 V~
±
10 %
50 – 60 Hz
P
max
= 80 VA