6 Troubleshooting
13
6
Troubleshooting
Electric shock hazard!
The discharging power pack is operated electrically and generates a
high electric voltage. In the event of any faults, there is a risk of an
electric shock.
• Faults may only be eliminated by a trained and qualified
electrician.
NOTE:
If the error cannot be removed in this way, return the discharging
power pack and ionizing unit for checking to HAUG GmbH & Co. KG
(the address is provided on the back of the envelope).
Fault
Cause
Troubleshooting
Ionisation
not
available
Mains
failure
Check mains fuse
No HV
Check fuse in discharging power
pack.
Check connections in discharging
power pack.
Check HV output of discharging power
pack using the Combicheck
(Accessories/spare parts, refer page
16).
Discharging
power pack
is damaged
Shut the discharging power pack
down immediately and secure against
switching on.
Ionizing unit
is dirty
Clean ionizing unit
Error in
ionization
system.
Perform work steps according to the
following flow chart. Refer page 15..